Napco Security Technologies GEM-DXRP3 manual Exiting the User Program Mode, Programming Example

Page 23

PROGRAMMING USER CODES

Exiting the User Program Mode

When you have completed programming or erasing User Codes, press Cto exit the User Program Mode.

Programming Example:

Example. Program the User 3 Code to “3784”. Note: For User Codes shorter than 6 digits, use G0for remaining digits.

1.Enter your User Code, followed by A.

2.Answer NO (press F) repeatedly until “17” is displayed, then press YES (E).

The display will scroll “P” followed by 4 digits, then “UP” (indicating User Programming) and the keypad lights will flash.

3.Press A followed by 03 (for User 3), then A again followed by 3784G0G0AAto program the code. (“UP” will display)

4.Press J to save the code.

5.Press Cto exit the Program Mode.

Notes:

If the system contains more than one keypad, only the keypad designated “No. 1” may be used for programming (if in doubt which is No. 1, ask your installer).

While in Program Mode, the ARMED and STATUS lights remain off and burglar and fire alarm functions are disabled. In selecting your codes, do not program repetitive numbers (1111), consecutive numbers (1234), your birth date, address, or other obvious combinations. Choose a code of up to six digits (a minimum of four is recommended, and required in UL installations). Note: Duplicate Codes are not allowed; therefore a duplicate Code entered in the LCD Window will erase when J is pressed.

While in Program Mode, the keypad beeps every 15 seconds.

If the keypad detects no Program Mode activity for more than 4 minutes, a steady tone will sound. Press Cto silence.

23

Image 23
Contents GEM-DXRP3 Keypad Important Test Your System Weekly IntroductionTable of Contents Keypad Controls & Indicators Emergency Buttons. Optional ButtonArea Button G. Selects Numerical Keys 1-9, 0. Used toSelectively Bypassing Zones Setting the Alarm Arming When LeavingArming the System Priority ArmingArea Arming Optional Managers ModeInstant Protection Protecting Yourself While on the PremisesBypassing Interior Zones ‰ Press D to activate Easy Exit on your system Disarming the System Turning OFF the AL ARM Disarming When ReturningAlarm Indication / Silencing an Alarm Fire-Zone Trouble Fire ProtectionImportant! Read Carefully Preparing a Fire Escape PlanFamily Rehearsal Floorplan Limitations of Fire Alarm Warning System Keypad Functions System troubles. For GEM-P9600/3200 panels only Keypad Functions Keypad Functions Keypad Functions Central Station Monitoring Communicator FeaturesSecurity Bypass/Unbypass Advanced FeaturesExit-Delay Restart Erasing a User Code Entering the User Program ModeProgramming User Codes Programming / Reprogramming a User CodeProgramming Example Exiting the User Program ModeClosing Window Optional. a GlossaryMore up to eight independent subsystems areas Glossary Trouble System Trouble Action Indication Condition System Trouble Error Codes06-NN 12-NN E19-00 What do I do if For more info TroubleshootingWithout charge to the original purchaser or user Napco Limited Warranty

GEM-DXRP3 specifications

Napco Security Technologies has established itself as a key player in the security industry, and one of its most notable offerings is the GEM-DXRP3 control panel. This versatile and user-friendly security system is designed for residential and commercial applications, delivering exceptional performance and reliability.

The GEM-DXRP3 operates as a wireless security system, leveraging advanced radio frequency (RF) technology to provide seamless communication between the control panel and peripheral devices. This eliminates the need for extensive wiring, making installation quicker and less disruptive, and allows for greater flexibility in terms of device placement. Its range of up to 2,500 feet in open areas ensures comprehensive coverage, accommodating diverse property layouts.

One of the standout features of the GEM-DXRP3 is its compatibility with a broad array of sensors and detectors. The system supports various devices, including door/window contacts, motion detectors, and glass break sensors, allowing users to tailor their security setup to their specific needs. Utilizing Napco's proprietary sensor technology, the panel ensures reliable detection and minimal false alarms.

The GEM-DXRP3 is equipped with a built-in keypad, providing users with easy access to system functions. This intuitive interface simplifies arming and disarming processes and enables quick adjustments to settings. Additionally, the system supports remote monitoring capabilities, allowing users to control and manage their security setup from virtually anywhere, enhancing convenience and peace of mind.

Another significant characteristic is its integrated Z-Wave technology, which adds home automation features. Users can control compatible smart devices, such as lights and thermostats, directly from the security panel or remotely via a mobile app. This integration not only enhances security but also improves energy efficiency and overall home convenience.

The GEM-DXRP3 is designed with scalability in mind. It accommodates a variety of expansion modules, allowing users to increase their security capacity as needed. This makes it an ideal solution for both small residential properties and larger commercial sites.

Durability and reliability are hallmarks of the GEM-DXRP3. With robust hardware and advanced firmware, the system is built to withstand various environmental conditions while providing consistent performance. Whether you're looking to secure a home or a business, Napco Security Technologies' GEM-DXRP3 remains a top choice, combining advanced features, ease of use, and reliability for superior security management.