Monessen Hearth SWB400I instruction manual Installation Preparation

Page 8

INSTALLATION PREPARATION

Survey the planned location for the fireplace for overhead plumbing or electrical wires, etc., that might complicate the installation or endanger persons installing or cleaning the chimney. Avoid a location where the chimney cap will be near abrupt changes in the roof shape, nearby wall or embankments, under or near trees or above the roof of a single story wing of a two story building as shown by Figure 8. All these conditions can cause turbulence or pressure conditions that can cause poor chimney draft and smoke spillage from the fireplace opening. Elbows may be used to offset the chimney to avoid obstructions or to locate the chimney cap in a preferred location. Refer to the sections of this manual pertaining to chimney offsets for instructions on proper elbow use. Poor installation or location of the chimney cap and/or components can cause wind blown rain to enter the chimney.

Be sure the selected location will allow a 14-1/2" square combustible material-free space for the chimney to pass through. If the chimney is to pass through living or storage spaces, be sure there is adequate space to enclose the chimney to avoid personal contact with, or damage to, the chimney. If the fireplace is to be installed on an outside wall, the surrounding walls (chase) should be constructed and insulated as shown by Figure 6. Failure to insulate the fireplace form outside temperatures will cause heat loss through and around the fireplace.

JOIST INSULATE SAME AS CEILING

FIGURE 6

SEE NOTES

SF FIRESTOP SPACER

NOTES:

1.MODEL SF FIRESTOP SPACER MUST BE USED.

2.LOCAL CODES MAY NOT REQUIRE FIRESTOPPING AT THE CEILING LEVEL FOR CHASE INSTALLATIONS, BUT IT IS RECOMMENDED FOR SAFETY AND REDUCING HEAT LOSS.

3.DO NOT INSULATE THE CHASE WITH BLOWN OR FILL TYPE INSULATION. INSULATION SHOULD ONLY CONTACT THE FIREPLACE AT POINTS WHERE THE FIREPLACE WOULD NORMALLY BE CONTACTED BY FRAMING MATERIALS .

8

SOLID

SURFACE

8' 0"

LEVEL

SCL TELESCOPING CHIMNEY CAP

FLAT CHASE FLASHING

R3672 (36" x 72")

OR

R4884 (48" x 84")

CHIMNEY SECTIONS "S" SERIES

INSULATE OUTSIDE

WALLS OF CHASE

SOLID CONTINUOUS

SURFACE

INSULATION (THERMAL BARRIERS)

OUTSIDE BASE

53D9033. Rev 1 03/03

Image 8
Contents SWB400I Deluxe Listing and Code Approvals Table of ContentsCongratulations Intended Product Usage Operation Guidelines Installation ClearancesTOP Corner Installation Fireplace LocationInstallation Preparation Single Story Installation with Attic Space Floor Protection Long MINFireplace Hearth Extension Fireplace Components See for Illustration of Models Described below MLK36 Fireplace Installation Fireplace InstallationChimney Installation 10/12 Chimney Offset Installation Chimney Offset and CAP Installation SF30 Firestop SpacerChimney CAP Installation Chimney Height and Offset Charts Straight RUN Chimney Sections Intermediate Height InchesChimney CAP Chase Installation Outside Combustion AIR Precautions & Recommendations AIRBasement Installation Combustion AIR Assembly GAS Appliance InstallationGAS Appliance Installation Trim Installation GAS Line PlumbingFraming Glass Door Installation and FAN Accessory JBI Junction BOX InstallationFireplace Operation Species Density Heat Value Maintenance and Safety DO’S DON’TS Parts Diagram and List SWB400I FireplaceThis page Intentionally Left Blank Limited Warranty Except BlowersYour Duties This page Intentionally Left Blank 53D9033. Rev 1 03/03 Appliance Installer

SWB400I specifications

The Monessen Hearth SWB400I is a versatile and efficient gas fireplace insert designed to enhance the aesthetic appeal and comfort of any home. It is an ideal solution for homeowners looking to upgrade their existing wood fireplace or transform an unutilized hearth into a modern, functional heating source.

One of the key features of the SWB400I is its impressive heating capacity. This insert can produce up to 40,000 BTUs, effectively warming areas of approximately 1,500 square feet. This makes it a powerful option for larger living spaces, ensuring consistent comfort during the colder months. The unit is equipped with a patented dual burner system that provides a realistic flame presentation while maximizing efficiency. Its efficient design means that users can enjoy a warm ambiance without worrying about excessive fuel consumption.

The Monessen SWB400I also boasts an advanced electronic ignition system, ensuring reliable starts every time. This technology eliminates the need for cumbersome matches or lighter fluid, making it user-friendly. In addition, the fireplace insert includes a built-in thermostat control, allowing homeowners to maintain the desired temperature with ease.

Another notable characteristic of the SWB400I is its customizable aesthetic options. Homeowners can choose from a variety of decorative fronts, including traditional and contemporary styles, to seamlessly integrate the insert into their home’s decor. The unit also features multiple media options, such as logs or contemporary glass pebbles, providing a personalized touch to the fireplace’s appearance.

Safety is a top priority with the SWB400I. It is equipped with a safety pilot system that automatically shuts off the gas supply in case of an emergency, ensuring peace of mind for users. Additionally, the fireplace insert comes with a removable safety screen that prevents accidental contact with the hot glass surface.

In summary, the Monessen Hearth SWB400I is a powerful, stylish, and efficient gas fireplace insert that combines innovative technology with customizable features. Its ability to produce significant heat, easy-to-use ignition system, and various aesthetic options make it a desirable addition to any home. Whether you're looking to increase your home's warmth or enhance its visual appeal, the SWB400I is an excellent choice for homeowners seeking quality and performance.