USING OPTIONAL AK-4 OUTSIDE AIR KIT

COMBUSTION AIR

1.Locate combustion air assembly at an exterior location which is not likely to be accidentally blocked in any manner. Locate assembly a minimum of 12" above the snow line to prevent blockage by snow accumulation.

2.Never mount the combustion air inlet assembly in a garage or storage area where combustible fumes such as gasoline might be drawn into the fireplace.

3.Combustion air can be drawn from the crawl space under a house when an adequate supply of air is provided by open ventilation.

4.CAUTION: Do not take combustion air from attic space or garage space.

5.Locate air supply inlet at least 3' away from any appliance vent terminal.

6.Avoid extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly. These conditions increase the resistance to the free flow of air through the duct. See Figures 16 through 19 for methods of installing the outside air for combustion assemblies.

Note: Fireplace model in illustrations may not be representative of your appliance.

Above

Snow

Level

Ground

Level

Basement

Wall

Inlet Grill in

8'max. Soffit

(Overhang)

 

Figure 17 - Concrete Slab Installation

Figure 16 - Basement Installation

(Optional Outside Air Runs)

Duct Extended

to Miss Joist

To Outside Wall

Inside Wall

Outside

Wall

Figure 18 - Installation Above Basement or

Figure 19 - 45° Corner Installation on

Crawl Space

Slab Floor

 

 

26D4721

15

Image 15
Contents Models LCUF32-F LCUF32-R LCUF36C-R What to do if YOU Smell GASRead and Save These Instructions Contents Important Safety Information InstallerOwner Never connect unit to private Before YOU Start Product FeaturesFirebox Dimensions General Installation InformationGeneral Installation Information and Location of Firebox Minimum Hearth DimensionsLocation of Firebox Clearance and Height Requirements Clearances and Height RequirementsTOP View Firebox Framing Corner InstallationCustom Cabinet GAS Line Installation Installing Canopy Canopy InstallationOptional Wide Canopy Optional Equipment and Illustrated Parts ListCombustion AIR Using Optional AK-4 Outside AIR KITInsulation Ring to Left Side of Fireplace Model AK-4 Combustion AIR AssemblyInstalling Model 403 Duct Connector Basic Warranty Five Year Warranty