GENERAL INSTALLATION INFORMATION

In planning the installation for the appliance it is necessary to determine where the unit is to be installed and whether optional accessories are desired. Gas supply piping should also be planned. The following steps represent the normal sequence of installation. Each installation is unique, however, and might require a different sequence.

1.Position firebox prior to framing or into prepared framing.

2.Plumb gas line. (Gas connections should only be performed by an experienced, licensed/certified tradesman).

3.Install vent-free gas log heater per the instructions provided with the vent-free gas log heater.

4.Complete finish wall material, surround and optional hearth extension to your individual taste.

FIREBOX EXTERNAL DIMENSIONS

D

F

E

H

 

LCUF32-F

LCUF36C-R

A

37"

41"

B

32"

36"

C

16"

18"

D

28⅞"

32"

E

18⅝"

20½"

F

23¼"

27¼"

G

28½"

30¼"

H

29⅞"

33⅞"

I

5⅜"

5⅜"

J

28⅜"

31¼"

K

1"

1"

L

34⅜"

37⅜"

M

73/16"

9¾"

A

I

C

J

B

G

L

2.50"2.50"

K

M

2.75"

Figure 1 - Firebox Dimensions

6

26D4721

Image 6
Contents Models LCUF32-F LCUF32-R LCUF36C-R What to do if YOU Smell GASRead and Save These Instructions Contents Important Safety Information InstallerOwner Never connect unit to private Product Features Before YOU StartGeneral Installation Information Firebox DimensionsGeneral Installation Information and Location of Firebox Minimum Hearth DimensionsLocation of Firebox Clearances and Height Requirements Clearance and Height RequirementsTOP View Corner Installation Firebox FramingCustom Cabinet GAS Line Installation Canopy Installation Installing CanopyOptional Equipment and Illustrated Parts List Optional Wide CanopyUsing Optional AK-4 Outside AIR KIT Combustion AIRModel AK-4 Combustion AIR Assembly Insulation Ring to Left Side of FireplaceInstalling Model 403 Duct Connector Five Year Warranty Basic Warranty