Napoleon Fireplaces EPA 1450 Blower Installation, Features Blower Service or Replacement, Wires

Page 9

3.The access panel can be removed by taking out the 8 #10 self taping screws. A 5/16” nut driver will be required to complete this job. Unplug wires from the thermal switch on the panel. See FIGURE 15.

4.Remove the securing wingnut from the blower mounting bracket, slide the bracket to the right and rotate the left side of the assembly out of the cavity to clear the blower motor. Disconnect the two wires from the blower motor. Remove the ground wire from the blower mounting bracket, then the assembly can be taken out of the rear cavity through the access door opening.

5.Remove the 3 screws that hold the blower to the mounting bracket. Service or replace the blower as required.

 

GROUND STUD

SECURING

 

 

WINGNUT

TAB

 

 

 

 

 

 

 

 

 

 

 

 

9

1150 BLOWER INSTALLATION

1.Remove the knock- out from the back of the fireplace.

2.Install the blow-

er and housing as shown using the 4 screws supplied.

FIGURE 19

FIGURE 16

6.Reinstall the blower assem- bly making sure the blower bracket is seated under the securing tab. FIGURE 16. Reattach the wire connectors. FIGURE 17.

7.Replace the gasket on the access door. To replace the access panel, reverse Step

3.

8.Replace the bricks into the firebox. Reinstall the door.

WIRES

FIGURE 17

3.Loosen the thermodisc bracket (2 screws) and slide the bracket forward until the thermodisc is touching the rear firebox and secure.

1150 FEATURES

FIGURE 20

1402 BLOWER SERVICE OR REPLACEMENT

1.Turn off all electrical power to the insert. Remove the glass door and set aside in a safe place.

2.Remove the two screws from the outer edge of the side panel(s).

3.Push the side panel toward the door and pull away from the insert, releasing the panel from the keyed slot.

4.Service or replace the blower(s) as required.

5.Re-install the side panel(s) by reversing the procedure.

BLOWER

 

G

 

HEAT

B

 

RHEOSTAT

BLOWER

SENSOR

W

Pot

Fender

Wood

Storage

(intended for

short term use)

FIGURE 18

LID LIFTER

HOOK

Remove the screw, as illustrated, from the preferred side of the stove rear. Secure the lid lifter hook, as illustrated, facing out to the side, or bend it towards the back.

W415-0512 / D / 07.16.08

Image 9
Contents Installation Operation Instructions Table of Contents Conditions and Limitations General Information Care of GlassCare of ALL Plated and Enameled Parts Installing the Legs Stove Installation Stove InstallationAlcove Installation Chimney ConnectionPedestal Models Outside AIR Mobile HomeWall PASS-THROUGH Adding Chimney SectionsPrior to Installation Hint for Installing Porcelain Enamel InsertsInstallation Into a Masonry Fireplace Fireplace InsertStove Models Optional BlowerLEG Models only Insert ModelsFeatures Blower Service or Replacement Blower InstallationWires Ground Stud Securing Wingnut TABFinishing Operation ASH Fender Maintenance Door Removal 1100C only Wood Pile MaintenanceDO’S DON’TSReplacement Parts ReplacementsFresh AIR Cover Plate Accessories31A W415-0512 / D Fireplace Service History W415-0512 / D W415-0512 / D W415-0512 / D