HEARTH
A hearth is NOT necessary but is recommended for aes- thetic purposes.
The finished height of the hearth must be accounted for when framing in the fireplace to ensure that there is 3/8" air space under the fireplace.
COLD CLIMATE INSTALLATION
WARNING: It is MANDATORY to have an insulated wall be- hind the fireplace, when the fireplace is being installed on an outside wall or chase.
LOG INSTALLATION
7
#2
#1
D
3.The bottom end of log #2 is pressed against the inner right side of the chamber. The underside branch of log #2 fits under the top end of log #1 to achieve the final position.
GLASS REPLACEMENT
LOG BASE
A
#1
B
1.Position log #1 as shown, so that the bottom end is pressed against the left inner side of the chamber. The log base is molded to cradle the underside of log #1, allowing it to rest diagonally, as shown.
Slot for glass | Slot for glass |
Insert the glass into the slots located at the sides of the viewing area. Slide the glass down the front of the unit until it rests against the bottom lip of the viewing area.
#2
C
2.For correct positoning of log #2, the top end of log #1 must be lifted up off the base, as shown.