8
THERMOSTAT AND THERMAL SENSOR INSTALLATION
This fi replace has two options for heat control.
First is a thermal controlled sensor, which comes plugged into the fi replace beside the main power cord. Figure 4. This sensor has no user temperature set points, it will turn off the heater when the sensor reaches its pre-set point, and will only turn the heater back on when it has cooled back down below this set point. On the low setting (green light) the set point is 16°C/61°F, on medium (orange light) 22°C/72°F and on high (red light) 28°C/82°F. This small sensor can be placed anywhere in the room within the length of the sensor wire, but it should not be placed near the top or front of the fi replace. Placing the sensor too close to the heater area of the fi replace will cause unwanted cycling of the heater.
Second is the option of a wall-mounted thermostat. Napoleon Part # W690-0001, W660-0081, or an equivalent low voltage thermostat. A wall thermostat can be used in place of the thermal control sensor. You must fi rst remove the sensor by unplugging it from the right side of the fi replace beside the main power cord. Replace the sensor with the wire harness provided in the manual baggie. Plug it into the fi replace and connect the other end to the thermostat. Figure 5&6. The thermostat should be placed as per the thermostat installa- tion instructions.
FIGURE 6