Napoleon Fireplaces EF30 manual Hardwire Installation, Electric Diagram

Page 9

HARDWIRE INSTALLATION

ELECTRIC DIAGRAM

9

HARD WIRING CONNECTION

FIGURE 4

 

10-10

 

 

 

F

 

 

L

 

 

A

 

 

M

M

E

~

O

 

 

M

 

 

TOR

9-9

 

 

1-1

H

 

EA

H

T

EA

ER

T

2

ER

1

 

 

2-2

 

BLO

 

 

W

 

 

E

 

M

 

~

R

 

M

2

 

O

 

TO

3

 

R

5W

 

3-3

 

P-L

2

3 5W

7-7

6-6

 

 

12-12

5-5 P-N0

PTC

8-8

t105!

POWER

If it is necessary to hard wire this

replace, a qualifi ed electrician may remove the cord connection, and wire the unit directly to the house hold wiring.

LThis fi replace must be electrically connected and grounded in ac-

cordance with local codes, if hard wired. In the absence of local codes, use the current CSA C22.1

 

 

MOTOR H2

H1+

 

 

 

 

 

FAN

LAMP FIRE

 

 

 

 

 

10-10

IF YOU

PUT IN THE TEMPERATURE

RG

 

MAIN

CONTROL

SENSOR ON THE WALL.PLS CHOOSE 2

SIP2

 

 

 

 

_

 

 

 

2

[

 

 

 

t

k +

REMO.

 

 

 

 

 

TEMPERATURE

 

 

 

 

 

 

 

 

 

CONTROL SWITCH

 

 

TEM.

 

 

t

 

 

 

 

1

 

 

 

 

 

 

 

 

 

TEMPERATURE

IF YOU USE THE

 

 

 

 

SENSOR

TEMPERATURE

 

 

 

 

 

SENSOR.PLS CHOOSE 1

 

 

 

RECEIVER

 

 

 

 

 

4-4 P-NI

NCANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70-

1996 NATIONAL ELECTRICAL CODE in the United States.

CAUTION Ensure all power is turned off before hard wiring this fi replace.

1.Remove cover plate located beside the power cord to reveal the 7/8” wire hole. Discard cover plate, screws and insert a box connector into the hole.

2.Remove the lower back panel from the fi replace to expose wiring.

3.Remove the power cord strain-relief from the side of the fi replace and cut the cord where shown below. This will be the hardwire connection point.

4.Feed the supply wires through the box connector and the grommet.

5.Using wire connectors connect the common (white) wires together, then the hot (black) wires, and then the ground (green) wires.

6.Ensure the newly connected wires are kept away from the rotating parts and the circuit board, and re-install the back panel.

NOTE: This fi replace must be serviced from the back, leave enough wire so that the fi replace can be removed from the enclosure with- out disconnecting the power supply wires.

1

2

FIGURE 5

Remove 2 screws on cover plate.

FIGURE 6

Hot Wire

Common Wire

Ground Wire

FIGURE 7

Power Cord

Cut

3

FIGURE 8

Box

Connector

4Final Connection

W415-0675 / A / 03.28.08

Image 9
Contents W415-0675 / a $10.00 Table of Contents Conditions and Limitations Important Instructions Listing Approvals Dimension SpecificationsGrounding Fireplace Locating FireplaceClearances to Combustibles InstallationThermostat and Thermal Sensor Installation Electric Diagram Hardwire InstallationFinishing Checklist Cold Climate InstallationFinishing HearthOperating Instructions Operating by Remote ControlPreparation for Maintenance MaintenanceCommon Observed Problems Flame Generation Bulb ReplacementCleaning Ember BED Bulb ReplacementReplacement Parts Replacement PartsAccessories DescriptionObserved Problem Possible Cause Remedy TroubleshootingW415-0675 / a