Storageflex RMC-LC10NG Ignitor electrode broken Replace electrode, ODS pilot lights but flame

Page 10

Problem

 

Possible Cause

 

What To Do

 

 

 

 

 

When control knob is pressed in

1.

Ignitor electrode positioned wrong.

1.

Reposition ignitor electrode.

and turned counterclockwise to

2.

Ignitor electrode broken.

2.

Replace electrode.

ignition, there is no spark at

3.

Ignitor cable pinched or broken.

3.

Free ignitor cable, if damaged, replace.

ODS pilot.

4.

Ignitor cable not connected to ignitor

4.

Connect cable to electrode

 

 

electrode.

 

 

 

 

 

 

When control knob is pressed in

1.

Gas supply turned off.

1. Turn gas supply on.

and turned counterclockwise to

2.

Control knob not in pilot position.

2. Turn control knob to pilot position.

ignition/pilot position there is

3.

Control knob not pressed in while in pilot

3.

Press in control while in pilot position.

spark but no ignition

 

position.

4.

Call a qualified service technician.

 

4.

ODS pilot is clogged.

 

 

 

5. Air in gas lines.

5.

Purge gas lines and repeat ignition operation.

 

 

 

ODS pilot lights but flame

1.Control knob not pressed long enough.

1. After ODS pilot lights, keep control knob

goes out when control knob

2.

Safety interlock is triggered.

 

pressed in approximately 30 seconds.

is released.

3.

Pilot flame not touching the thermocouple.

2. Wait one minute, repeat ignition operation.

 

 

Problem could be result of one or both of

3.

Contact your gas company, gas supplier or

 

 

the following:

 

qualified service technician.

 

 

• Partially clogged ODS pilot orifice.

 

 

 

 

• Low gas pressure.

 

 

 

4. Thermocouple damaged.

4.

Replace thermocouple.

 

5. Thermocouple connection loose at gas

5.

Hand tight until snug then tighten 1/4 turn with

 

 

control valve.

 

a wrench.

 

6.

Gas control valve damaged.

6.

Replace gas control.

 

 

 

 

 

Burner does not light after ODS

1.

Burner orifice clogged.

1.

Clean burner orifice.

pilot is lit.

2.

Gas supply pressure is very low.

2.

Contact gas supplier.

 

 

 

 

 

Delayed ignition.

1.

Main burner carry over ports clogged.

1.

Clean main burner ports.

 

2.

Gas supply pressure is very low.

2.

Contact gas supplier.

 

 

 

 

 

Burner backfiring during

1.

Burner orifice is clogged.

1.

Clean burner orifice.

operation.

2.

Burner ports damaged.

2.

Replace burner.

 

 

 

 

 

Yellow flames during burner

1.

Not enough air

1.

Check air passageways and burner for dirt and

operation. (RMC-LC)

 

 

 

debris (Refer to Maintenance section)

 

 

 

 

 

Burner plaque(s) does not glow.

1.

Plaque(s) is damaged.

1.

Replace burner.

(RMC-LI)

2.

Inlet gas pressure too low.

2.

Contact local gas supplier.

 

3.

Control knob set between locked positions.

3. Turn control knob until it locks at desired

 

 

 

 

setting.

 

 

 

 

Slight smoke and odor during

1.

Residues from manufacturing processes.

1. Will stop after a few hours of operation.

initial operation.

 

 

 

 

 

 

 

 

Heater produces a whistling

1. Air passageways blocked.

1.

Check minimum installation clearances and air

noise when burner is lit.

 

 

 

passageways for debris.

 

2. Air in gas line.

2.

Operate burner until the air is completely

 

 

 

 

purged.

 

 

 

 

 

10

Image 10
Contents 20,000 Btu/hr Blue Flame Heaters Models RMC-LC10NG10,000 Btu/hr 30,000 Btu/hrNever use propane in a unit designed for natural gas PrecautionsSafe Operation of Your Legacy Vent Free Heater Heater does not monitor the air for COLocal Codes Product Features Safety DevicePiezo Ignition System Provide Adequate Combustion Ventilation AIR Items Needed for Heater InstallationGAS Type Attach Mounting Screws to Wall Preparing for InstallationLocating the Heater A bathroom A recreational vehicleFloor Installation Wall Anchor MethodConnect to GAS Supply Leak Testing Heater GAS ConnectionPressure Test GAS Supply Piping System Lighting Instructions Push in gas control knob slightly and turn counterclockwiseManual Lighting Instruction To Turn OFF GAS to AppliancePilot and Burning Inspection Setting Clean main burner portsOperation. RMC-LC Debris Refer to Maintenance section Ignitor electrode broken Replace electrodeCleaning AIR Passageways Unit Casings Burner and ODS Pilot CleaningImpurities in air Causing products near heater Item/Model Number Page RMC-LC10NG/LP Accessories Warranty What your dealer can furnish, contact