Storageflex RMC-LC10LP - 10, (F) - 2, RMC-LC20LP(T) Wall Anchor Method, Floor Installation

Page 6

WALL ANCHOR METHOD

When mounting heater to hollow walls (wall areas between studs) or solid walls (concrete or masonry) it may be neces- sary to use wall anchors.

1.Place paper template on wall maintaining minimum clear- ance. Be sure template is level.

2.Drill holes at marked locations using 5/16”drill bit.

For solid walls, concrete or masonry, drill holes at least 1”deep.

3.Insert plastic anchor. Tap anchor flush to wall. (Fig. 4)

4.Insert screw into wall anchor leaving screw head out far enough to attach heater. (Fig. 4)

5.Hang heater on mounting screws in holes provided at the rear of the heater.

Fig. 4 Wall anchor.

FLOOR INSTALLATION

1.Heater may only be installed on a noncombustible flat surface. Where the flooring is carpeting, tile or of other combustible material other than wood flooring, maintain the minimum clearances to the floor as shown in figure 2 or else use a metal or wood panel (not supplied) extending the full width and depth of the appliance.

2.Measure heater mounting screw location “X” as desired above floor. (Fig. 5)

3.Use enclosed “paper template” for proper distance between holes. Be sure template is level. It maybe necessary to use plastic or lead anchors for plaster walls.

4.Leave screw head out from wall far enough to attach heater.

x = 173/4"

45 CM

30,000 BTU/hr units

161/2"

42 CM

18 & 20,000 BTU/hr units

141/4"

36 CM

6 & 10,000 BTU/hr units

Fig. 5 Optional wall mounting screws for floor installation.

6

Image 6
Contents 20,000 Btu/hr Blue Flame Heaters Models RMC-LC10NG10,000 Btu/hr 30,000 Btu/hrNever use propane in a unit designed for natural gas PrecautionsSafe Operation of Your Legacy Vent Free Heater Heater does not monitor the air for COProduct Features Safety Device Local CodesPiezo Ignition System Items Needed for Heater Installation Provide Adequate Combustion Ventilation AIRGAS Type Attach Mounting Screws to Wall Preparing for InstallationLocating the Heater A bathroom A recreational vehicleFloor Installation Wall Anchor MethodLeak Testing Heater GAS Connection Connect to GAS SupplyPressure Test GAS Supply Piping System Lighting Instructions Push in gas control knob slightly and turn counterclockwiseTo Turn OFF GAS to Appliance Manual Lighting InstructionPilot and Burning Inspection Setting Clean main burner portsOperation. RMC-LC Debris Refer to Maintenance section Ignitor electrode broken Replace electrodeBurner and ODS Pilot Cleaning Cleaning AIR Passageways Unit CasingsImpurities in air Causing products near heater Item/Model Number Page RMC-LC10NG/LP Accessories Warranty What your dealer can furnish, contact