Vermont Casting VCBV20TP - 20, VCPV10TN Troubleshooting, Problem Possible Cause What To Do

Page 10

Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater

Troubleshooting

Problem

 

Possible Cause

 

What To Do

 

 

 

 

 

 

When control knob is pressed

1.

Ignitor electrode positioned wrong.

1.

Replace ignitor electrode.

in and turned counterclockwise

2.

Ignitor electrode broken.

2.

Replace electrode.

to ignition, there is no spark at

3.

Ignitor cable pinched or broken.

3.

Free ignitor cable, if damaged

ODS pilot.

 

 

 

replace.

 

4.

Ignitor cable not connected to ignitor

4.

Connect cable to electrode.

 

 

electrode.

 

 

 

When control knob is pressed

1.

Gas supply turned off.

1.

Turn gas supply on.

 

in and turned counterclockwise

2.

Control knob not in pilot position.

2.

Turn control knob to pilot position.

to ignition/pilot position, there

3.

Control knob not pressed in while in

3.

Press in control while in pilot

is spark but no ignition.

 

pilot position.

 

position.

 

4.

ODS pilot is clogged.

4.

Call a qualified service technician.

 

5.

Air in gas lines.

5.

Purge gas lines and repeat ignition

 

 

 

 

operation.

ODS pilot lights but flame goes

1.

Control knob not pressed long

1.

After ODS pilot lights, keep control

out when control knob is

 

enough.

 

knob pressed in approximately 30

released.

 

 

 

seconds.

 

2.

Safety interlock is triggered.

2.

Wait one minute, repeat ignition

 

 

 

 

operation.

 

3.

Pilot flame not touching the thermo-

3.

Contact your gas company, gas

 

 

couple. Problem could be result of

 

supplier or qualified service

 

 

one or both of the following:

 

technician.

 

 

Partially clogged ODS pilot orifice.

 

 

 

 

 

Low gas pressure.

4.

Replace thermocouple.

 

4.

Thermocouple damaged.

 

5.

Thermocouple connection loose at

5.

Hand tight until snug then tighten

 

 

gas control valve.

 

1/4 turn with a wrench.

 

6.

Gas control valve damaged.

6.

Replace gas control.

Burner does not light after ODS

1.

Burner orifice clogged.

1.

Clean burner orifice.

pilot is lit.

2.

Gas supply pressure is very low.

2.

Contact gas supplier.

Delayed ignition.

1.

Main burner carry over ports

1.

Clean main burner ports.

 

 

clogged.

2.

Contact gas supplier.

 

2.

Gas supply pressure is very low.

Burner backfiring during

1.

Burner orifice is clogged or clogged.

1.

Clean or replace burner orifice.

 

operation.

2.

Burner damaged.

2.

Replace burner.

 

3.

Gas regulator defective.

3.

Replace gas regulator.

Yellow flames during burner

1. Not enough air.

1. Check air passageways and

operation. (VCBV)

 

 

 

burner for dirt and debris. (Refer to

 

 

 

 

Maintenance section.)

Burner plaque(s) does not

1.

Plaque(s) is damaged.

1.

Replace burner.

glow. (VCPV)

2.

Inlet gas pressure is too low.

2.

Contact local gas supplier.

 

3.

Control knob set between locked

3.

Turn control knob until it locks at

 

 

positions.

 

desired setting.

Slight smoke and odor during

1.

Residues from manufacturing

1.

Will stop after a few hours of

initial operation.

 

processes.

 

operation.

Heater produces a whistling

1.

Air passageways blocked.

1.

Check minimum installation

noise when burner is lit.

 

 

 

clearances and air passageways

 

 

 

 

for debris.

 

2.

Air in gas line.

2.

Operate burner until the air is

 

 

 

 

completely purged.

 

 

 

 

 

 

10

Image 10
Contents Unvented Gas-Fired Room Heater General Safety Information Table of ContentsPiezo Ignition System Product Features Safety DeviceLocal Codes Thermostatic Heat ControlProvide for Adequate Ventilation InstallationItems Needed for Heater Installation Gas TypeAttach Mounting Screws to Wall Preparing for InstallationWall Anchor Method Floor Installation Connect to Gas SupplyTurn off the heater Lighting Instructions Operating InstructionsTo Turn Off Gas To Heater Manual Lighting Instructions Pilot and Burner InspectionTroubleshooting Problem Possible Cause What To DoBurner and ODS Pilot Cleaning MaintenanceCleaning Air Passageways Unit Casings VCBVTN/ TP Unvented Room Heater VCBVTN/ TP VCPVTN/ TP Unvented Room Heater Accessories VCPVTN/TPWarranty

VCBV30TN, VCBV10TP - 10, VCBV20TN, VCBV10TN, VCBV20TP - 20 specifications

Vermont Casting has long been synonymous with quality and innovation in the world of wood and gas stoves. Among their impressive line-up, the VCPV30TP, VCBV10TP, VCBV20TN, VCBV10TN, and VCBV30TP models stand out for their performance and craftsmanship.

The VCPV30TP is a 30,000 BTU direct vent gas stove that combines classic styling with modern technology. One of its main features is its impressive efficiency, achieving an AFUE rating that assures homeowners of reduced energy costs and environmental impact. The stove's innovative catalytic combustion system enables a cleaner burn and enhanced heat output, making it an excellent choice for both new constructions and renovations. The unit is equipped with a large viewing window, framed by cast iron that not only adds to its rustic charm but also provides excellent heat retention.

On the other hand, the VCBV10TP and VCBV20TN models offer different BTU outputs, catering to various heating needs. The VCBV10TP produces up to 10,000 BTUs, perfect for smaller spaces, while the VCBV20TN, with its 20,000 BTU output, is ideal for medium-sized areas. Both units feature user-friendly thermostatic controls that allow for precise temperature regulation, contributing to comfort and efficiency. Their cast iron construction ensures durability and heat retention, allowing users to enjoy consistent warmth over extended periods.

The VCBV10TN and VCBV30TP-30 models also share similar engineering excellence. The VCBV10TN is designed to heat efficiently while maintaining a compact profile, ideal for homes with limited space. The VCBV30TP-30, with its enhanced features, focuses not only on performance but also on aesthetics. It boasts a stunning traditional design that complements a variety of interior styles, while still packing robust heating technologies.

All models are designed for easy installation and maintenance, with features like clean-out access and adjustable air controls. This thoughtful engineering reflects Vermont Casting's commitment to creating products that balance performance, beauty, and practicality. In summary, the VCPV30TP, VCBV10TP, VCBV20TN, VCBV10TN, and VCBV30TP-30 embody the brand's legacy of quality and innovation, ensuring that homeowners not only stay warm but do so in style.