Vermont Casting VCPV18TP - 18, VCPV10TN Installation, Provide for Adequate Ventilation, Gas Type

Page 4

Vermont Castings VCBVTN/TP & VCPVTN/TP Room Heater

Installation

Installation Requirements

Fresh Air for Combustion and Ventilation

WARNING:

This heater must have fresh air for proper opera- tion. If not, poor fuel combustion could result. Read the following instructions to insure proper fresh air for this and other fuel-burning appli- ances in your home.

Modern construction standards have resulted in homes that are highly energy-efficient and that allow little heat loss. Your home needs to breathe, however, and all fuel-burning appliances need fresh air to function properly and safely. Exhaust fans, clothes dryers, fireplaces and other fuel burning appliances all use the air inside the building. If the available fresh air supply is insufficient to meet the demands of these appliances, problems can result.

Provide for Adequate Ventilation

Any space within a home can be classified in these categories:

Unusually tight construction: The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air. Unusually tight construction is defined as construction where:

Walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm or less with openings gasketed or sealed and;

Caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall/ceiling joints, between wall panels, at penetrations for plumbing, electrical and gas lines, and at other openings.

Unconfined space: An unconfined space whose volume is not less than 50 cubic feet for each 1,000 Btu/Hr of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors are consid- ered a part of the unconfined space.

Confined space: A confined space whose volume is less than 50 cubic feet for each 1,000 Btu/Hr of the aggregate input rating of all appliances in that space.

WARNING: You must provide additional ventilation air in a confined space.

For proper operation of the unit, provide fresh air opening(s) to the room. Follow the National Fuel Code NFPA54/ANSI Z223.1, for required size of combustion and ventilation openings.

NOTICE: A qualified service technician should install heater. Follow all local codes.

Gas Type

Verify the type of gas supply to be used, either natural gas or LP (Propane), and make sure the marking on the appliance rating plate agrees with that of the supply gas. The rating plate is located on the side of the heater, which indicates the type of gas that the heater is orificed for.

Items Needed for Heater Installation

Before installing the heater, make sure you have these items:

Gas piping (check local codes)

Test gauge connection

Sealant (resistant to LP gases) - approved thread compound

Manual shut-off valve *

Sediment trap - where required

Ground joint union

Tee joint and pipe wrench

*An installer supplied design-certified manual shut-off valve with 1/8” NPT tap connection.

Locating the Heater

This heater is designed to be mounted on a wall. The heater may also be located on the floor away from a wall. An optional floor mounting base is required and cn be purchased from your dealer.

WARNING: Never install the heater:

in a bathroom,

in a recreational vehicle,

where curtains, furniture, clothing or other flammable objects are less than 36” from the front, top or sides of the heater,

as a fireplace insert,

in high traffic areas, or

in windy or drafty areas.

WARNING: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation may cause mildew formation from too much moisture content. See National Fuel Code for Fresh Air for Combustion and Ventilation.

4

Image 4
Contents Unvented Gas-Fired Room Heater General Safety Information Table of ContentsProduct Features Safety Device Local CodesPiezo Ignition System Thermostatic Heat ControlInstallation Items Needed for Heater InstallationProvide for Adequate Ventilation Gas TypeAttach Mounting Screws to Wall Preparing for InstallationWall Anchor Method Floor Installation Connect to Gas SupplyTurn off the heater Lighting Instructions Operating InstructionsTo Turn Off Gas To Heater Manual Lighting Instructions Pilot and Burner InspectionTroubleshooting Problem Possible Cause What To DoBurner and ODS Pilot Cleaning MaintenanceCleaning Air Passageways Unit Casings VCBVTN/ TP Unvented Room Heater VCBVTN/ TP VCPVTN/ TP Unvented Room Heater Accessories VCPVTN/TPWarranty

VCBV30TN, VCBV10TP - 10, VCBV20TN, VCBV10TN, VCBV20TP - 20 specifications

Vermont Casting has long been synonymous with quality and innovation in the world of wood and gas stoves. Among their impressive line-up, the VCPV30TP, VCBV10TP, VCBV20TN, VCBV10TN, and VCBV30TP models stand out for their performance and craftsmanship.

The VCPV30TP is a 30,000 BTU direct vent gas stove that combines classic styling with modern technology. One of its main features is its impressive efficiency, achieving an AFUE rating that assures homeowners of reduced energy costs and environmental impact. The stove's innovative catalytic combustion system enables a cleaner burn and enhanced heat output, making it an excellent choice for both new constructions and renovations. The unit is equipped with a large viewing window, framed by cast iron that not only adds to its rustic charm but also provides excellent heat retention.

On the other hand, the VCBV10TP and VCBV20TN models offer different BTU outputs, catering to various heating needs. The VCBV10TP produces up to 10,000 BTUs, perfect for smaller spaces, while the VCBV20TN, with its 20,000 BTU output, is ideal for medium-sized areas. Both units feature user-friendly thermostatic controls that allow for precise temperature regulation, contributing to comfort and efficiency. Their cast iron construction ensures durability and heat retention, allowing users to enjoy consistent warmth over extended periods.

The VCBV10TN and VCBV30TP-30 models also share similar engineering excellence. The VCBV10TN is designed to heat efficiently while maintaining a compact profile, ideal for homes with limited space. The VCBV30TP-30, with its enhanced features, focuses not only on performance but also on aesthetics. It boasts a stunning traditional design that complements a variety of interior styles, while still packing robust heating technologies.

All models are designed for easy installation and maintenance, with features like clean-out access and adjustable air controls. This thoughtful engineering reflects Vermont Casting's commitment to creating products that balance performance, beauty, and practicality. In summary, the VCPV30TP, VCBV10TP, VCBV20TN, VCBV10TN, and VCBV30TP-30 embody the brand's legacy of quality and innovation, ensuring that homeowners not only stay warm but do so in style.