Vanguard Heating VMH3000TN Cleaning and Maintenance, Replacement Parts, Service Hints

Page 19

OWNER’S MANUAL

CLEANING AND MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, pet hair, bedding material, etc.

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, and lint. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We rec- ommend that you clean the unit every 2,500 hours of operation or every three months.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recom- mend using compressed air no greater than 30 PSI. Your local computer store, hard- ware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the direc- tions on the can. If you don't follow direc- tions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 29).

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hairs with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 30). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Injector Holder

Ports/Slots

Burner

Tube

Primary Air Inlet

Holes

Figure 29 - Injector Holder On Outlet Burner Tube

Pilot Air Inlet

Hole

Pilot Assembly

Figure 30 - Pilot Inlet Air Hole

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabi- net to remove dust.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Techni- cal Service Department at 1-800-323-5190 for referral information.

When calling DESA International, have ready

your name

your address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the defec- tive part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information.

When calling DESA International, have ready

model number of your heater

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burner(s) will have delayed ignition

heater will not produce specified heat

When Gas Quality Is Bad

pilot will not stay lit

burner(s) will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.

104431

19

Image 19
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualLocal Codes Safety InformationUnpacking AssemblyProduct Features Product IdentificationAssembling and Attaching Brass Trim Attaching Brass Front Trim to Front PanelConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Locating Heater InstallationInstallation Items Check GAS TypeThermostat Sensing Bulb Installation OptionsMounting Heater to Wall Placing Heater On Mounting Bracket Installing Bottom Mounting ScrewsMounting Heater to Optional Hearth Base Mounting Heater on Optional Hearth BaseSecuring Hearth Base to Floor Mounting Heater to Optional Mantel Connecting to GAS SupplyAssembling Mantel Pressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections To Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Heater Lighting InstructionsPilot Flame Pattern Inspecting BurnerBurner Flame Pattern Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Replacement Parts Cleaning and MaintenanceService Hints VMH3000TN Illustrated Parts BREAKDOWN21KEY VMH3000TN Description QTY Parts ListTechnical Service SpecificationsPremier Mantel AccessoriesEquipment Shutoff Valve GA5010 FAN KitsInternational Warranty Information

VMH3000TN specifications

The Vanguard Heating VMH3000TN is a state-of-the-art heating solution designed to deliver efficient warmth and comfort in a variety of environments. Its innovative features and advanced technologies make it an ideal choice for both residential and commercial applications.

One of the standout features of the VMH3000TN is its powerful heating capacity. With a substantial output, this unit can quickly warm large spaces, ensuring that every corner of the room reaches a comfortable temperature. This makes it perfect for homes, offices, workshops, and other facilities that require reliable heat distribution.

The VMH3000TN comes equipped with advanced energy-efficient technology. It incorporates a high-performance heat exchanger that maximizes thermal efficiency, helping to reduce energy consumption and lower heating costs. This makes it an environmentally-friendly option for consumers looking to minimize their carbon footprint while enjoying the benefits of effective heating.

Another notable characteristic of the VMH3000TN is its user-friendly interface. The product features intuitive controls that allow users to customize their heating experience easily. With programmable settings, users can set specific heating schedules according to their lifestyle, ensuring that spaces are warm when needed without excessive energy use.

Safety is also a priority in the design of the VMH3000TN. It is equipped with multiple safety features, including overheat protection and a reliable thermostat. These systems work together to prevent potential hazards, giving users peace of mind while using the heater.

Durability and reliability are additional attributes of this model. Constructed with high-quality materials, the VMH3000TN is built to withstand the rigors of daily use. Its robust design ensures longevity, making it a worthwhile investment for those seeking a long-term heating solution.

The VMH3000TN is also designed with versatility in mind. Its sleek and compact design enables it to fit seamlessly into a variety of spaces and decor styles. It can be easily installed in homes, garages, or offices without taking up excessive space.

In summary, the Vanguard Heating VMH3000TN is a powerful, efficient, and reliable heating solution that caters to diverse heating needs. Its array of features, safety mechanisms, and user-friendly operation make it a top choice for consumers seeking effective climate control. Whether for personal comfort or professional use, the VMH3000TN promises to deliver warm and inviting spaces all winter long.