CLEANING AND MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, pet hair, etc.

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, and lint. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We rec- ommend that you clean the unit every 2,500 hours of operation or every three months.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recom- mend using compressed air no greater than 30 PSI. Your local computer store, hard- ware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the direc- tions on the can. If you don't follow direc- tions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt.

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hairs with a soft cloth or vacuum cleaner nozzle.

5.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 30). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Pilot Air Inlet

Hole

Pilot Assembly

Figure 30 - Pilot Inlet Air Hole

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabi- net to remove dust.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Techni- cal Service Department at 1-800-323-5190 for referral information.

When calling DESA International, have ready

your name

your address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the defec- tive part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information.

When calling DESA International, have ready

model number of your heater

the replacement part number

106056

19

Image 19
Contents What to do if YOU Smell GAS VENT-FREE PROPANE/LP GAS MINI-HEARTHHEATERProduct Features Safety InformationLocal Codes Assembling Heater AssemblyProduct Identification UnpackingLocate brass front trim in brass trim package Attaching Brass Front Trim to Front PanelAssembling and Attaching Brass Trim May result in property damage or personal injuryConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationInstallation Items Locate heater where moving ve- hicle will not hit itThermostat Sensing Bulb Installation OptionsMounting Heater to Wall Attaching To Wall Anchor Method Installing Bottom Mounting ScrewsMounting Heater on Optional Hearth Base Placing Heater On Mounting BracketMounting Heater to Optional Hearth Base Mounting Heater to Optional MantelSecuring Hearth Base to Floor External Regulator with Vent Pointing Down Connecting to GAS SupplyTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Checking GAS ConnectionsTo Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Heater Lighting InstructionsPilot Flame Pattern Manual Lighting ProcedureInspecting Burner Thermostat Control OperationAfter ODS/pilot lights, keep control TroubleshootingPilot assembly Safety interlock system has been trigPane/LP company Maintenance,Top Gas odor even when control knob is in OFFGas leak. See Warning statement at Replacement Parts Cleaning and MaintenanceVMH3000TPS Illustrated Parts BREAKDOWN21KEY VMH3000TPS Description QTY Parts ListWhen Gas Pressure Is Too Low SpecificationsTechnical Service Service HintsAccessories Warranty Information

VMH3000TPS specifications

The Vanguard Heating VMH3000TPS is a state-of-the-art heating unit designed to provide efficient and reliable warmth for residential and commercial spaces. This model stands out for its exceptional performance, advanced technologies, and user-friendly features that cater to diverse heating needs.

One of the main features of the VMH3000TPS is its powerful heating capacity. With a robust output, it can effectively heat large areas, making it suitable for open-plan homes, offices, and industrial spaces. The unit operates quietly, ensuring that users can enjoy a comfortable environment without the disruptive noise often associated with heating systems.

The VMH3000TPS incorporates cutting-edge energy efficiency technologies. It is engineered to consume less energy while delivering optimal performance, which translates into lower utility bills and a reduced carbon footprint. This model features advanced insulation materials that minimize heat loss and allow the unit to maintain a consistent temperature throughout the space.

Another notable characteristic of the VMH3000TPS is its smart control system. Users can easily adjust the temperature settings through a user-friendly digital interface. This includes programmable schedules that enable users to set heating times according to their preferences. Additionally, the unit is compatible with smart home systems, allowing for remote access and control via smartphones or other devices.

Safety is a top priority in the design of the VMH3000TPS. The unit is equipped with multiple safety features such as overheat protection, tip-over switches, and flame failure devices. These ensure that the heater operates safely in all conditions, providing peace of mind to users.

Moreover, the VMH3000TPS is built with durability in mind. Constructed from high-quality materials, it is designed to withstand the rigors of daily use while maintaining aesthetics. The sleek, modern design allows it to blend seamlessly with any décor, making it an attractive addition to any space.

In summary, the Vanguard Heating VMH3000TPS is a high-performance, energy-efficient heating solution that combines advanced technology with user-friendly features. With its powerful output, smart controls, and emphasis on safety and durability, it is an excellent choice for anyone looking to improve their heating system. Whether for home or commercial use, the VMH3000TPS promises to deliver comfort and efficiency throughout the heating season.