Vanguard Heating VMH3000TPS installation manual Safety Information, Local Codes, Product Features

Page 2

®

GAS RESIDENTIAL HEATERS

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monox- ide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alco- hol, and those at high altitudes.

Propane/LP Gas: Propane/LP gas is odor- less. An odor-making agent is added to gas. The odor helps you detect a gas leak. How- ever, the odor added to gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its controls can be dangerous.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This heater shall not be installed in a bedroom or bathroom.

5.Never install the heater

in a recreational vehicle.

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater.

as a fireplace insert.

in high traffic areas.

in windy or drafty areas.

6.This heater needs fresh, outside air ven- tilation to run properly. This heater has an oxygen depletion sensor (ODS) pilot light safety system. The ODS shuts down the heater if not enough fresh air is available. See Fresh Air for Combus- tion and Ventilation, pages 5 through 7.

7.Before using furniture polish, wax, car- pet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white pow- der residue within burner box or on adjacent walls or furniture.

8.If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.

9.Do not run heater

where flammable liquids or vapors are used or stored.

under dusty conditions.

10.Never place any objects on the heater.

11.Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow surface to cool before touching.

12.Carefully supervise young children when they are in same room with heater.

13.Make sure screen is in place before run- ning heater.

14.To prevent the creation of soot, follow the instructions in Cleaning and Main- tenance, page 19.

15.Do not use heater if any part has been under water. Immediately call a quali-

fied service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

16.Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater.

17.Operating heater above elevations of 4,500 feet could cause pilot outage.

18.To prevent performance problems, do not use a propane/LP fuel tank of less than 100 lbs. capacity.

WARNING: Do not use a blower insert, heat exchanger insert, or other accessory not approved for use with this heater.

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223.1, also known as NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

PRODUCT

FEATURES

SAFETY DEVICE

This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

THERMOSTATIC HEAT CONTROL

This heater has a thermostat sensing bulb and a control valve. This results in the great- est heater comfort. This can also result in lower gas bills.

2

106056-01

Image 2
Contents VENT-FREE PROPANE/LP GAS MINI-HEARTHHEATER What to do if YOU Smell GASLocal Codes Safety InformationProduct Features Unpacking AssemblyProduct Identification Assembling HeaterMay result in property damage or personal injury Attaching Brass Front Trim to Front PanelAssembling and Attaching Brass Trim Locate brass front trim in brass trim packageUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Locate heater where moving ve- hicle will not hit it InstallationInstallation Items Check GAS TypeMounting Heater to Wall Installation OptionsThermostat Sensing Bulb Placing Heater On Mounting Bracket Installing Bottom Mounting ScrewsMounting Heater on Optional Hearth Base Attaching To Wall Anchor MethodSecuring Hearth Base to Floor Mounting Heater to Optional MantelMounting Heater to Optional Hearth Base Connecting to GAS Supply External Regulator with Vent Pointing DownChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaLighting Instructions For Your Safety Read Before LightingOperating Heater To Turn OFF GAS To ApplianceThermostat Control Operation Manual Lighting ProcedureInspecting Burner Pilot Flame PatternSafety interlock system has been trig TroubleshootingPilot assembly After ODS/pilot lights, keep controlMaintenance, Pane/LP companyGas leak. See Warning statement at Gas odor even when control knob is in OFFTop Cleaning and Maintenance Replacement PartsIllustrated Parts BREAKDOWN21 VMH3000TPSParts List KEY VMH3000TPS Description QTYService Hints SpecificationsTechnical Service When Gas Pressure Is Too LowAccessories Warranty Information

VMH3000TPS specifications

The Vanguard Heating VMH3000TPS is a state-of-the-art heating unit designed to provide efficient and reliable warmth for residential and commercial spaces. This model stands out for its exceptional performance, advanced technologies, and user-friendly features that cater to diverse heating needs.

One of the main features of the VMH3000TPS is its powerful heating capacity. With a robust output, it can effectively heat large areas, making it suitable for open-plan homes, offices, and industrial spaces. The unit operates quietly, ensuring that users can enjoy a comfortable environment without the disruptive noise often associated with heating systems.

The VMH3000TPS incorporates cutting-edge energy efficiency technologies. It is engineered to consume less energy while delivering optimal performance, which translates into lower utility bills and a reduced carbon footprint. This model features advanced insulation materials that minimize heat loss and allow the unit to maintain a consistent temperature throughout the space.

Another notable characteristic of the VMH3000TPS is its smart control system. Users can easily adjust the temperature settings through a user-friendly digital interface. This includes programmable schedules that enable users to set heating times according to their preferences. Additionally, the unit is compatible with smart home systems, allowing for remote access and control via smartphones or other devices.

Safety is a top priority in the design of the VMH3000TPS. The unit is equipped with multiple safety features such as overheat protection, tip-over switches, and flame failure devices. These ensure that the heater operates safely in all conditions, providing peace of mind to users.

Moreover, the VMH3000TPS is built with durability in mind. Constructed from high-quality materials, it is designed to withstand the rigors of daily use while maintaining aesthetics. The sleek, modern design allows it to blend seamlessly with any décor, making it an attractive addition to any space.

In summary, the Vanguard Heating VMH3000TPS is a high-performance, energy-efficient heating solution that combines advanced technology with user-friendly features. With its powerful output, smart controls, and emphasis on safety and durability, it is an excellent choice for anyone looking to improve their heating system. Whether for home or commercial use, the VMH3000TPS promises to deliver comfort and efficiency throughout the heating season.