Lennox Hearth SHGL-18MP-R dimensions Millivolt Wiring Diagram, Btu/Hr, Regulator Gas Inlet Valve

Page 10

10

 

 

THERMOPILE

 

 

PILOT (O.D.S.)

 

 

 

ASSEMBY

 

 

MILLIVOLT VALVE

 

 

 

 

WHITE

 

 

 

RED

 

 

 

OFF

IGNITION

 

 

 

OPTIONAL

WHITE

 

WIRE

 

 

 

 

 

REMOTE CONTROL

 

 

 

(MILLIVOLT)

BLACK

 

 

 

 

ON

 

 

 

ON/OFF SWITCH

 

 

 

AND PILOT IGNITOR

 

 

MILLIVOLT WIRING DIAGRAM

 

VENTED/UNVENTED GAS LOG APPLIANCE TECHNICAL CHART FOR MILLIVOLT LOG SET

 

BTU/HR

 

 

Regulator

Gas Inlet

Valve

 

Model No.

Input

Gas Type

Ignition

Pres. Setting

Pressure*

Operation

Orifice Size

 

 

 

 

 

 

 

 

SHGL - 18VN-R

36,000

Natural

Piezo

1.6 – 3.5" w.c.

Max. 10.5" w.c.

Millivolt

0.113

 

24,000

 

 

 

Min. 5.0" w.c.

 

 

SHGL - 18VP-R

36,000

Propane/LPG

Piezo

6.3 – 10.0" w.c.

Max. 13" w.c.

Millivolt

0.069

 

24,000

 

 

 

Min. 11" w.c.

 

 

SHGL - 24VN-R

39,000

Natural

Piezo

1.6 – 3.5" w.c.

Max. 10.5" w.c.

Millivolt

0.119

 

28,000

 

 

 

Min. 5.0" w.c.

 

 

SHGL - 24VP-R

39,000

Propane/LPG

Piezo

6.3 – 10.0" w.c.

Max. 13" w.c.

Millivolt

0.072

 

29,000

 

 

 

Min. 11" w.c.

 

 

 

 

 

 

 

 

 

 

* For the purpose of input adjustment.

NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

Image 10
Contents OTL Report no -L-11-5 18 & 24 Dual-Listed Gas Log Sets P/N 850,021M REV. B 03/2007Important Safety Information Table of ContentsGeneral Information Combustion and Ventilation AIR CodesExample Clearances PreinstallationCheck Gas Type Vent Free ApplicationsRequirements for Safe Installation Noncombustible Material Heights and Mantel LocationChecking Gas Connections InstallationConsult all local codes Gas Pressure CheckPeriodically check the positioning of all logs Placing the LogsFlame Appearance Replacement Parts Burner And Flame CharacteristicsCleaning and Servicing Operation and Care of Your ApplianceWall Switch Kit Standard Remote Control System Model RCLDeluxe Remote Control System Model RC-STAT Accessory ComponentsRegulator Gas Inlet Valve Millivolt Wiring DiagramBTU/HR Input Gas TypeManual Wiring Diagram Lighting Instructions Operating Instructions Manual Control ModelsWhat to do if YOU Smell GAS To Turn OFF GAS to ApplianceTurn Control Knob to IGN Position Manual Lighting Instructions Normal service To OFF. Do not forceLighting Instructions Millivolt To Turn OFF GAS to ApplianceObserved Problem Possible Cause RemedyReplacement Parts List Millivolt 18N/18P 24N/24P DescriptionReplacement Parts Millivolt 113 Propane Pilot ShownReplacement Parts List Manual Replacement Parts Manual Propane Pilot Shown 1112850,021M REV. B 03/2007