Lennox Hearth SHGL-24VN-R dimensions Lighting Instructions Millivolt, To Turn OFF GAS to Appliance

Page 14

LIGHTING INSTRUCTIONS – MILLIVOLT

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION

MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A.This appliance has a pilot which must be lighted with a piezo ignitor. When lighting the pilot, follow these instructions exactly.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Extinguish any open flame.

Open windows.

Do not light any appliance.

Do not touch any electrical switches.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone.

If your gas supplier cannot be reached, call the fire depart- ment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician.

Force or attempted repair may result in a fire or an explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this page.

2.Access the lower control compartment.

3.Turn remote wall switch to “OFF.”

4.Verify main line shut-off valve is open.

5.Push in gas control knob slightly and turn clockwise

to “OFF.”

 

 

 

OUT

IN

TPTH

 

 

 

 

TP

 

 

OFF

 

 

 

 

P

 

 

 

 

 

 

 

 

I

 

 

 

 

L

TH

 

 

it

O

 

 

T

 

 

 

NO

 

 

 

 

 

 

 

P

 

 

 

I

 

 

L

 

 

 

TO

 

 

 

Note: Knob cannot be turned from “PILOT” to “OFF” unless the knob is pushed in slightly. Do not force.

6.Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety information above on this page. If you do not smell gas, go to the next step.

7.Push in gas control knob slightly and turn counterclockwise

to “PILOT.”

8.Push in control knob all the way and hold in. Immediately light the pilot by triggering the spark ignitor (pushing the button) until pilot lights. Continue to hold the control knob in for about 1 ¹⁄₂ minutes after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

If knob does not pop up when

released, stop and immediately call your service technician or gas supplier.

If pilot will not stay lit after several tries, turn the control knob to “OFF” and call your service technician or gas supplier.

9.Turn gas control knob counterclockwise to “ON.”

10.Close lower control compartment.

14

TO TURN OFF GAS TO APPLIANCE

1.

Turn remote wall switch “OFF.” The pilot will remain lit for

4.

Depress gas control knob slightly and turn clockwise

 

normal service.

 

to “OFF.” Do not force.

2.

For complete shutdown, turn remote wall switch to “OFF.”

5.

Close lower control compartment.

3.Access the lower control compartment.

Image 14
Contents OTL Report no -L-11-5 18 & 24 Dual-Listed Gas Log Sets P/N 850,021M REV. B 03/2007General Information Table of ContentsImportant Safety Information Example CodesCombustion and Ventilation AIR Clearances PreinstallationCheck Gas Type Vent Free ApplicationsRequirements for Safe Installation Noncombustible Material Heights and Mantel LocationChecking Gas Connections InstallationConsult all local codes Gas Pressure CheckFlame Appearance Placing the LogsPeriodically check the positioning of all logs Replacement Parts Burner And Flame CharacteristicsCleaning and Servicing Operation and Care of Your ApplianceWall Switch Kit Standard Remote Control System Model RCLDeluxe Remote Control System Model RC-STAT Accessory ComponentsRegulator Gas Inlet Valve Millivolt Wiring DiagramBTU/HR Input Gas TypeManual Wiring Diagram Lighting Instructions Operating Instructions Manual Control ModelsWhat to do if YOU Smell GAS To Turn OFF GAS to ApplianceTurn Control Knob to IGN Position Manual Lighting Instructions Normal service To OFF. Do not forceLighting Instructions Millivolt To Turn OFF GAS to ApplianceObserved Problem Possible Cause RemedyReplacement Parts List Millivolt 18N/18P 24N/24P DescriptionReplacement Parts Millivolt 113 Propane Pilot ShownReplacement Parts List Manual Replacement Parts Manual Propane Pilot Shown 1112850,021M REV. B 03/2007