Amcor PLM 9000E, PLM 15000E Setting the temperature, Mode switch, Fan speed, Heat, Timer

Page 6
Timer example

Setting the temperature

If you want to change the set temperature press or to set the temperature. The 2 digit display will indicate the set temperature.

Note: Reaching the set temperature depends on the room and outdoor climatic conditions.

Mode switch

Press the button successively until the icon representing the desired mode is appearing (=> Cool => Fan => Heat => etc). On the LCD-display you will see:

Cooling Fan only Heat

Each time the unit starts, it starts operating in cool mode with a set temperature of 22°C. The fan speed will be selected automatically. Heat mode is only available on EH models.

Fan speed

If you prefer a constant fan speed instead of the auto fan speed, press the button successively; the fan icon on the LCD-display will rotate accordingly.

Fast - for the turbo speed

Normal - for the medium speed

Slow - for the slow speed

Alternating - for the auto fan speed (in the cooling mode only!)

Heat

EH models feature a 1650 W electric heater that can heat a room on cooler days. With the mode switch select , set the desired temperature and the unit will heat until this temperature is reached. Fan speed is selected automatically. Do not place the unit near anything that could catch fire or be scorched. Do not obstruct the air outlet. The heat function will operate with or without the hose attached.

Timer

For all of the following TIMER programming, proceed firstly with these standard steps:

Press the button briefly; the 2 left digits of the 4 digits on the LCD display are flashing.

Press or to adjust the hour.

Press the button briefly again, the 2 right digits of the 4 digits are flashing.

Press or to adjust the minutes of the clock in intervals of 5 minutes. The timer is set. After 10 seconds the time display returns.

Programming the timer for ON - when the unit is OFF.

• Perform the standard steps as described above.

The circular time scale will be on between the ON programmed times until 24:00. The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes until it reaches the ON timer time, then the black segments in the circular time scale will disappear.

Programming the timer for OFF - when the unit is RUNNING.

• Perform the standard steps as described above.

The circular time scale will be on between the present time to the OFF programmed time. The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes until it reaches the OFF timer time, then the black segments in the circular time scale will disappear.

6

Image 6
Contents PLM Electric Connection How to wire a 13 amp plugThank YOU Green and Yellow Earth Blue Neutral Brown LiveSafety Instructions Parts Installation Setting the clockOperation Timer Setting the temperatureMode switch Fan speedRepeat OFF and on Cancelling the timer functionSleep mode Repeat on and OFFDehumification Filter installationAIR Filter For continuous drainageRemote Control Emptying the Internal Water ContainerScreen filter must always be used Cleaning Trouble ShootingProblem Cause Solution Model 9000E 12000E 15000E Technical DataStorage ReminderTsbfm

PLM 9000E, PLM 15000E specifications

Amcor, a global leader in packaging solutions, has introduced innovative machinery designed to cater to various industrial needs, including the PLM 9000E and PLM 15000E models. These advanced packaging machines have been engineered to improve efficiency, precision, and sustainability in packaging processes.

The Amcor PLM 9000E is renowned for its flexibility and speed. This model is capable of producing a wide range of packaging formats, from pouches to stand-up bags. One of its standout features is its high-speed filling and sealing technology, which ensures that products are packed swiftly without compromising quality. This machine is designed with user-friendly interfaces, allowing operators to make quick adjustments, reducing downtime and increasing productivity.

Key technologies incorporated in the PLM 9000E include advanced servo drive systems that provide precise control over movement and operation, enhancing the accuracy of packaging. Its modular design allows for easy upgrades and maintenance, ensuring the longevity of the equipment. Additionally, the machine is built with energy-efficient components that optimize power consumption, contributing to lower operational costs and a reduced environmental footprint.

On the other hand, the Amcor PLM 15000E takes packaging automation to the next level. With a higher production capacity, this model is suitable for large-scale operations. It features intelligent controls that leverage data analytics to monitor performance and output in real time, allowing for proactive maintenance and minimizing unexpected downtimes. The PLM 15000E also integrates seamlessly with other production line systems, enhancing overall operational synergy.

This model boasts an innovative sealing technology that guarantees airtight seals, critical for preserving product freshness and extending shelf life. It also offers enhanced compatibility with various materials, including biodegradable options, supporting Amcor's commitment to sustainability. The PLM 15000E is designed with safety protocols in mind, featuring safety mechanisms that protect operators while ensuring smooth machine operation.

Both models reflect Amcor's dedication to innovation, efficiency, and sustainability. With features tailored to meet the demands of modern packaging, the PLM 9000E and PLM 15000E stand out as essential tools for businesses seeking to optimize their packaging processes while adhering to environmentally responsible practices. Amcor continues to lead the way in creating packaging solutions that align with both industry standards and consumer expectations.