Majestic Appliances UVSRC36A Optional Procedure For Cold Climate Installations, Seal Seams

Page 6

UVSRC Vent-Free Fireboxes

 

D

1/2"

 

 

 

 

C

5"

A

1/2” Clearance

 

 

not Required at

 

 

This Point

 

B

B

A

 

 

Front View

 

 

Side View

 

 

 

 

 

T226

 

A

B

C

 

D

UVSRC36A

39¹⁄₄”

44¹⁄₄”

21”

 

22”

UVSRC42A

45¹⁄₄”

44¹⁄₄”

22”

 

32”

Fig. 4 Framing dimensions.

The normal gas connection is 1/2" NPT, made at the left side facing the unit. If a right side connection is desired, the connecting pipe must be led at the rear of the fireplace to terminate at the left hand side for connec- tion to the fireplace.

Piping should be tested for leaks prior to final wall installation. Test for leaks using soap and water solution after completing the connection. DO NOT USE OPEN FLAME.

Step 6: Optional Procedure For Cold Climate Installations

The insulation and sealing of the enclosure around the fireplace is very important in cold climates. If the enclosure is insulated and sealed properly, you can avoid future cold air problems. The time taken to install the firebox correctly is well worthwhile. The following steps are to stop potential cold air problems.

6

Insulation of the Fireplace Enclosure

When in a chase or an outside wall, the fireplace enclosure should be insulated like any other wall of your home. Insulation should be installed on the outside wall(s) and the wall above the fireplace.

Insulate to Seal Under the Fireplace

Insulating under the fireplace is beneficial for installa- tions on a concrete slab. The fireplace should be placed on insulating board. It is important that a hard, rigid surface be maintained, so do not use fiberglass insula- tion for this purpose.

CAUTION: WHEN INSTALLING A FIREPLACE IN AN INSULATED ENCLOSURE, BE SURE TO MAINTAIN ALL MARKED AIR SPACES.

Seal Seams

Seal the seams of the fireplace where the outer wall meets the bottom pan and the front face. Also seal between the fireplace and finishing materials. Use high temperature caulk. Refer to Figure 6 for details of sealing spaces between the fireplace and finishing materials. Note the small amount of insulation installed across the top of the fireplace and down the sides as a backing for the caulk.

Noncombustible

Insulation

Side Refractory

 

1"

 

 

Min.

Refractory Cement

 

 

Fireplace

 

 

Outer Wrap

 

1/2” Gas Pipe

 

 

 

 

T227

Fig. 5 Gas line installation.

 

Finishing Material

 

 

 

Stud

 

Noncombustible Material

 

 

Caulking or Sealant

Insulation

 

 

 

Side View

 

Stand-

Noncombustible

 

off

Insulation

 

 

Finishing Material

 

Top View

Caulking or Sealant

FP568

 

 

Fig. 6 Sealing spaces between fireplace and finishing

 

materials.

 

 

 

20007435

Image 6
Contents UVSRC42A Table of Contents Fireplace Dimensions UVSRC36A and UVSRC42A specifications and framing dimensionsInstallation Instructions Installing the Firebox Insulate to Seal Under the Fireplace Optional Procedure For Cold Climate InstallationsInsulation of the Fireplace Enclosure Seal SeamsBlower Installation Pre-Wiring of Junction BoxElectrical Services Finishing the FireplaceUVSRC36A Blower Installation UVSRC42A InstallationServicing Accessories DescriptionLimited Lifetime Warranty CFM Specialty Home Products