COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
CHAPTER 5 SERVICE MODE
5-68 T
PD-ME Use it to execute automatic density correction for text mode (to read PD-
DENS output).
Using the Mode
1) While keeping the following in mind, place the PD-DENS output on the
copyboard glass as indicated:
The printed side must face down.
The whiter side (lighter; of the 17 gradations) must face the vertical size
plate.
The output must be placed in relation to the index in the left rear of the
copyboard glass.
2) Select <PD-ME> to highlight, and press the OK key.
3) The scanning lamp goes ON and OFF 13 times, making as many scans
automatically.
If ‘OK’ is indicated, end the work.
If ‘NG’ is indicated, discussed under “Standards and Adjustments” in
Chapter 3.
F05-501-06
Place it so that
the printed side
faces down.
PD-DENS output
COPIER>FUNCTION>DENS