CHAPTER 6 SELF DIAGNOSIS

E248

0001

A difference is discovered between the ID in EEPROM read when the main

 

power switch is turned on and the ID in ROM upon comparison.

0002

The data read does not match the data written to EEPROM.

0003

A difference is discovered between the ID of EEPROM and the ID of ROM

 

upon comparison while writing data.

Main cause

The EEPROM (IC403) of the reader controller PCB is faulty. The reader

 

controller PCB is faulty.

Action

1.Execute the following in service mode: COPIER>FUNCTION>CLEAR>CON. Is the proem corrected?

YES: End. After executing the service mode, be sure to enter the service mode data newly.

2.EE-PROM, Reader controller PCB

Try replacing the EE-PROM. Is the problem corrected?

YES: End. After replacement, be sure to enter the service mode data newly.

NO: Replace the rear controller PCB. After replacement, be sure to en- ter the service mode date newly.

E261

0000

The intervals of zero-cross signals deviate from the tolerance range while

 

the fixing heater is supplied with power.

Main cause

The wiring is faulty (short circuit, open circuit). The main power supply

 

PCB is faulty. The DC controller PCB is faulty.

Making Corrections

1. Connectors

Are the connector J205 on the main power supply PCB and the connector J308B on the DC controller PCB securely connected? (zero-cross signal: J205-7 <-> J308B-1)

NO: Connect the connectors securely.

2. Main power supply PCB, Main controller PCB

Try replacing the main power supply PCB. Is the problem corrected? YES: End.

NO: Replace the DC controller PCB.

6-18 T

COPYRIGHT © 2001 CANON INC.

CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001