COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
CHAPTER 6 SELF DIAGNOSIS
6-38 T

1.3 Saddle Finisher-G1 Error Codes

When the finisher’s self diagnostic mechanism has gone ON, it may be reset by turning
off and then on its host machine.
The host machine can still generate copies if the finisher cable is disconnected and the de-
livery path is set to the delivery tray of the host machine.

1.3.1 Error Code of the Finisher Unit

E501
0001 The communication between the finisher controller PCB and the puncher
drive PCB is disrupted.
Main cause The finisher controller PCB is faulty. The puncher drive PCB is faulty.
E505
0001 When the main power is turned on, the checksum of the finisher controller
PCB has a fault.
0002 When the main power is turned on, the checksum of the puncher driverPCB
has a fault.
Main cause The EEPROM is faulty. The finisher controller PCB is faulty. The puncher
driver PCB is faulty.
E510
0001 The feeding roller does not leave home position when the feed motor is
driven for 2 sec.
0002 The feeding roller does not return to home position when the feed motor is
driven for 2 sec.
Main cause The feed motor (M1) is faulty. The setting roller home position sensor is
faulty. The finisher controller PCB is faulty.