CHAPTER 6 SELF DIAGNOSIS

E805

 

The clock signal is absent for 5 sec or more after the fan drive signal has

 

been generated. The detail codes of the fans in question are as follows:

0001

developing fan (FM1)

 

0002

fixing fan (FM2)

 

0003

curl reducing fan (FM4)

 

0004

curl reducing fan (FM5)

 

0005

electrical unit fan (FM3)

 

Main cause

The fan wiring is faulty (short circuit, open circuit). The fan is faulty. The

 

DC controller PCB is faulty.

 

Action

 

 

 

 

1. Foreign matter

 

 

Is there foreign matter that prevents the rotation of the fan?

 

YES: Remove the foreign matter.

 

 

2. Wiring, Connector

 

 

Are the wiring and connector of the fan normal?

 

Developing fan (FM1):

DC controller PCB (J302B)

 

Fixing fan (FM2):

DC controller PCB (J308B)

 

Curl reducing fan (FM4):

DC controller PCB (J311B)

 

Curl reducing fan (FM5):

DC controller PCB (J311B)

 

Electrical unit fan (FM3):

main controller PCB (J1028)

NO: Correct the wiring and the connection.

3. Fan, DC controller PCB

Try replacing the fan. Is the problem corrected? YES: End.

NO: Replace the DC controller PCB.

COPYRIGHT © 2001 CANON INC.

CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001

6-35 T

Page 654
Image 654
Canon IR3300, IR2800, IR2200 manual E805