CHAPTER 3 STANDARDS AND ADJUSTMENTS

2.2 Mounting the Motor Unit

1)Engage the pulley [2] of the motor unit [1] with the belt [3].

2)Using two screws [4], mount the motor unit [1] temporarily.

3)Fit the spring [5] to apply tension to the belt [3].

4)Check to make sure that the belt [3] is vertical.

5)While taking care not to hold the scan- ning lamp [1] or the reflecting shade [2], move the No. 1 mirror base [3] back and forth two to three times to make a check once again.

6)Tighten the two screws to secure the motor unit in place.

[4]

[6]

[1]

[3]

[2]

[5]

F03-202-01

[3]

[2]

[1]

F03-202-02

COPYRIGHT © 2001 CANON INC.