CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS

4.1.2 The DC power is absent.

1. AC power supply

Is the rated AC voltage present at the connector J6 (between 1 and 3) of the main controller PCB and at the connector J100 (between 1 and 3) of the composite power supply PCB?

NO: See “The AC power is absent.”

2. Fuse (F1)

Is the fuse on the composite power supply PCB blown ? YES: Remove the cause of the fuse, and replace the fuse.

3. Main power supply PCB, Composite power supply PCB

Is the output voltage of each power supply PCB normal?

a. Main Power Supply PCB

b. Composite Power Supply

Connector

Output voltage

Connector

Output voltage

J202-1, 3, 5

24VU1-SW

J120-1, 4

5V

J203-2

24VU2

J121-1, 2, 3

3VA2

J204-1, 3, 7, 8, 9

24VU3

J121-4, 5

3VA1

J206-2

24VU3

J121-11,12,13

3VB

J206-3

5V

J122-1, 2

5V

 

 

J124-3, 4

3VA1

 

 

J124-6

3VB

 

 

J124-9, 10

5V

 

 

J126-2, 3, 5, 7

13V

YES: Check the wiring from each power supply PCB to each load.

NO: Replace the faulty power supply PCB.

COPYRIGHT © 2001 CANON INC.

CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001

4-29 T

Page 461