CHAPTER 6 SELF DIAGNOSIS

E064

0000

The presence of a high-voltage error is communicated by the composite

 

power supply PCB. (The output for primary charging, developing, or trans-

 

fer has deviated from a specific level of voltage.)

Main cause

The contact has poor connection. The wiring is faulty. The composite power

 

supply PCB is faulty. The DC controller PCB is faulty.

Action

 

 

 

1. Contact

 

 

Is any of the contacts of the primary charging roller, developing assembly,

 

or transfer charging roller soiled? Or, is there poor contact?

 

YES: Clean the contact, and set it once again.

 

 

2. Wiring

 

 

Is the wiring between the contacts for the following normal: DC controller

 

PCB (J301), composite power supply PCB (J136), primary charging roller,

 

developing assembly, transfer charging roller?

 

a. DC controller PCB (J301) <-> composite power supply PCB (J136)

 

b. composite power supply PCB (J130-7) <-> primary charging roller con-

 

tact

 

c. composite power supply PCB (J130-1) <-> developing assembly contact

 

d. composite power supply PCB (FT133) <-> transfer roller contact

NO: Correct the connection.

3. Composite power supply PCB, DC controller PCB

Try replacing the composite power supply PCB. Is the problem corrected? YES: Yes.

NO: Replace the DC controller PCB.

6-12 T

COPYRIGHT © 2001 CANON INC.

CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001

Page 631
Image 631
Canon IR2800, IR3300, IR2200 manual E064, 12 T