CHAPTER 6 SELF DIAGNOSIS

E220

0001

A fault is detected on the inverter PCB for the scanning lamp.

Main cause

The inverter PCB is faulty. The reader controller PCB is faulty.

Action

1. Wiring

Is the wiring from the scanning lamp to the reader controller PCB normal? NO: Connect the connector firmly, and correct or replace the wiring.

2. Inverter PCB, Reader controller PCB

Try replacing the lamp inverter PCB. Is the problem corrected? YES: End.

NO: Replace the reader controller PCB.

E225

0000

A specific level cannot be attained for the signal during CCD gain correc-

 

tion at power-on.

0002

The edge gain correction level is different from the correction level for the

 

preceding sheet by a specific level or more.

Main cause

The scanning lamp is faulty. The CCD PCB is faulty. The rear controller

 

PCB is faulty.

Action

1. Scanning lamp (LAMP1)

Is the lamp ON during the initial operation after the main power switch is turned on?

NO: Replace the scanning lamp.

2. CCD unit, Reader controller PCB

Try replacing the CCD unit. Is the problem corrected? YES: End.

NO: Replace the reader controller PCB.