Canon IR2200, IR3300 Temperature Correction of the DC Bias, Humidity Correction of the AC Bias

Models: IR2800 IR3300 IR2200

1 724
Download 724 pages 52.71 Kb
Page 170
Image 170

CHAPTER 4 IMAGE FORMATION SYSTEM

2.4 Temperature Correction of the DC Bias

When the temperature inside the machine increases, the resistance of the photosensitive drum will decrease, thereby lowering the charging characteristics. To ensure a stable poten- tial level, the drum sensor (U701) mounted to the rear side plate is used to check the tem- perature inside the machine; when the temperature increases, the absolute value of the DC bias level is increased.

Primary DCbias

-800V

 

-750V

 

 

(reference

 

 

value)

 

 

23˚C

40˚C

LowHigh

Machine inside temperature

F04-204-01

2.5 Humidity Correction of the AC Bias

The current level of the AC bias needs to be kept on the higher side to prevent uneven charging because of a lower changing efficiency occurring in a low-humidity environment. The AC bias, therefore, is varied as shown in F04-205-01 to suit the readings of the environ- ment sensor (humidity). When the resistance of the drum surface decreases because of ad- vancing wear, the current level is decreased to facilitate the flow of current.

Counter reading: 0 to 10,000 sheets

Counter reading: 10,001 or higher

 

2300µA

 

 

 

 

 

bias

2150µA

 

 

 

 

 

AC

 

 

 

 

 

 

 

 

 

 

 

Primary

2000µA

 

 

 

 

 

 

 

 

 

 

 

 

Low

35%

High

Low

35%

High

 

Humidity

Humidity

 

 

 

F04-205-01

 

 

4-6 P

COPYRIGHT © 2001 CANON INC.

CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001

Page 170
Image 170
Canon IR2200, IR3300 Temperature Correction of the DC Bias, Humidity Correction of the AC Bias, F04-204-01, F04-205-01