CHAPTER 6 SELF DIAGNOSIS

 

 

 

 

 

 

E733

 

0001

A fault is detected by the main controller PCB in the communication be-

 

tween the DC controller PCB and the main controller PCB.

Main cause

The connector has poor connection. The DC controller PCB is faulty.

Action

1. Connector, DC controller PCB

Is the connection between the connector J1015 on the main controller PCB and the conductor J316 on the DC controlled PCB normal?

NO: Correct the connection.

YES: Replace the DC controller PCB.

E737

0000

During self diagnosis at power-on, the DRAM check finds a fault in the

 

main controller PCB.

Main cause

The connection of the IC socket is faulty. The main controller PCB is faulty.

Action

1. Connection

Is the DRAM fitted to the socket securely? NO: Fit the DRAM securely.

2. DRAM, Main controller PCB

Try replacing the DRAM. Is the problem corrected? YES: End.

NO: Replace the main controller PCB.

COPYRIGHT © 2001 CANON INC.

CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001

6-31 T

Page 650
Image 650
Canon IR2200, IR3300, IR2800 manual E733, E737