CHAPTER 6 SELF DIAGNOSIS

E901

0000

The motor ready signal does not arrive within 1.3 sec after the pedestal

 

main motor drive signal is generated.

Main cause

The connector has poor connector. The pedestal main motor is faulty. The

 

main power supply PCB is faulty. The pedestal controller PCB is faulty.

 

The DC controller PCB is faulty.

Action

1. Connector

Is the wiring between the pedestal controller PCB and the main power sup- ply PCB and between the main power supply PCB and the DC controller PCB normal?

NO: Correct the wiring.

2. Main power supply PCB

Is the voltage between J206-2 (+) and J206-1 (-) on the main power supply PCB about 24 V?

NO: Replace the main power supply PCB.

3. Pedestal main motor

Try replacing the pedestal main motor. Is the problem corrected? YES: End.

4. Pedestal controller PCB, DC controller PCB

Try replacing the pedestal controller PCB. Is the problem corrected? YES: End.

NO: Replace the DC controller PCB.

6-36 T

COPYRIGHT © 2001 CANON INC.

CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001

Page 655
Image 655
Canon IR2800, IR3300, IR2200 manual E901, 36 T