4)Free the claw [2] of the inlet lower guide [1], and slide it to the rear to re- move.

Take care not to damage the fix- ing roller. When mounting, avoid pushing it against the fix- ing roller.

5)Lift the rear of the fixing roller assem- bly [1], and slide it to the rear to re- move.

6)Detach the two roller bushings [2] from the fixing roller [1].

7)Remove the conducting rubber [3].

[1]

[2]

F06-401-10

[1]

F06-401-11

[3] [2]

[1]

[2]

F06-401-12

COPYRIGHT © 2001 CANON INC.