CHAPTER 11 ENVELOPE FEEDER ATTACHMENT-B1

3)Thread the edge of the spring [1] that comes as an attachment so as to fit it through the catch 1 [2] and then the catch 2 [3].

4)Holding the bottom (1st and 2nd loops) of the spring, fit it through the catch 3 [4]; then, thread it until distance A is about 15 mm from the catch 2 [3].

At this time, check to make sure that the spring is firmly on the bottom plate.

5.3 Changing the Size

5.3.1 Changing the Size

1)Match the lifter [1] and the side guide plate [2] against the size positioning line of the envelope feeder in relation to the edges of the side guide plate; then, secure them in place by using two mounting screws [3] each.

Take care so that the side guide plate will not extend beyond the envelope feeder (as by choosing the wrong mounting hole). See the next page for the correct mounting hole.

[2][3]

A

[1][4]

F11-502-03

[2]

[1]

[2]

[3]

 

[3]

 

 

F11-503-01

11-8 P

COPYRIGHT © 2001 CANON INC.

CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001

Page 385
Image 385
Canon IR2800, IR3300, IR2200 manual Changing the Size, F11-502-03 F11-503-01 11-8 P