CHAPTER 6 SELF DIAGNOSIS

 

 

 

 

 

 

E710

 

0001

When the main power is turned on, the communication IC (IPC) on the

 

reader controller PCB cannot be initialized.

0002

When the main power is turned on, the communication IC (IPC) on the DC

 

controller PCB cannot be initialized.

0003

When the main power is trend on, the communication IC (IPC) on the main

 

controller PCB cannot be initialized.

Main cause

The DC controller PCB is faulty. The reader controller PCB is faulty. The

 

machine controller PCB is faulty.

Action

Malfunction, PCBs

Turn off and then on the main power switch. Is the problem corrected? YES: End.

NO: If E7100001, replace the reader controller PCB. If E710-002, replace the DC controller PCB.

If E71-0003, replace the main controller PCB.

COPYRIGHT © 2001 CANON INC.

CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001

6-25 T

Page 644
Image 644
Canon IR2200, IR3300, IR2800 manual E710