CHAPTER 1 MAINTENANCE AND INSPECTION

6.Feeding System

Clean the following: (1) feeding assembly base, (2) fixing inlet guide (upper, lower), (3) transfer guide, (4) pre-registration assembly (paper lint).

7.Image Formation System

Clean the following: developing member, (2) developing assembly bottom.

8.Optical Unit

Clean the following with a special tool: (1) bending mirror.

9.Image Formation System

Inspect and, as necessary, remove the waste toner and then clean the waste toner case; or, replace the waste toner case if any:

1.Be sure to dispose of the water toner according to the standards im- posed by the government concerned.

2.Do not dispose of waste toner into fire (to avoid explosion).

10.Make test copies.

11.Make sample copies.

12.Check the operation of the leakage breaker.

While the power switch is ON, press the test switch of the leakage breaker to make sure that it operates normally (i.e., the lever goes OFF to cut the power).

If the leakage breaker fails to operate normally, replace it and make a check once again. To reset,

After making a check, turn off the main power switch (the lever should go ON), and then turn on the main power switch.

13.Put the sample copies into order, and clean up the area around the machine.

14.Fill out the Service Book, and report to the person in charge; put a description of the check made on the operation of the leakage breaker in the Service Book.

COPYRIGHT © 2001 CANON INC.

CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001

1-5 T

Page 398
Image 398
Canon IR2200, IR3300, IR2800 manual Maintenance and Inspection