CHAPTER 6 SELF DIAGNOSIS

E032

0001

The DA unit connection is disconnected (after connection).

Main cause

The DA unit is faulty. The main controller PCB is faulty.

Action

1. Connector

Is the DA unit connected securely? NO: Connect it securely.

2. DA controller, Main controller PCB

Try replacing the DA unit. Is the problem corrected? YES: End.

NO: Replace the main controller PCB.