CHAPTER 5 PICK-UP/FEEDING SYSTEM

5.2 Identifying the Size of Paper in the Multifeeder

5.2.1 Detecting the Width of Paper

The width of paper is detected by a variable resistor operating in conjunction with the movement of the slide guide. The slide guide is set when the user adjusts the multifeeder tray to suit the paper placed on it.

5.2.2 Rear/Front Registration

The rear/front registration of the multifeeder may be adjusted by turning the screw on the slide guide.

5.2.3 Identifying the Length of Paper

The length of paper is detected with reference to the period of time during which the pre- registration paper sensor (PS10) remains ON while copies are being made. The maximum size of paper is 432 × 279 mm (11×17).

Slide guide (rear)

Variable resistor

Multifeeder tray

Slide guide (front)

F05-602-01

COPIER>ADJUST>CST-ADJ>MF-A4R

Use it to adjust the paper width basic value of A4R paper for the manual feed tray.

COPIER>ADJUST>CSRT-ADJ>MF-A6R

Use it to adjust the paper width basic value of A6R for the manual feed tray. COPIER>ADJUST>CST-ADJ>MF-A4

Use it to adjust the paper width basic value of A4 paper for the manual feed tray.