CHAPTER 4 IMAGE FORMATION SYSTEM

3 Controlling the Transfer Charging Roller Bias

3.1 Outline

Part 2>Chapter 5>7.8.3 “Controlling the Transfer Roller Charging”

The machine’s transfer charging is a direct charging method that uses a transfer charging roller. A DC bias is applied to the transfer charging roller.

The following relate to the transfer charging system:

[1]Turning on/off the bias.

[2]Controlling the DC bias to a specific voltage/current level.

[3]Controlling the detection of transfer charging roller resistance (ATVC control)

[4]Controlling the output by operation mode

[5]Controlling the output by the environment sensor (humidity)

Composite power supply PCB

 

24 VDC input from

 

 

+24V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

main power supply J135

 

 

 

 

 

 

 

 

 

 

Transfer

 

 

 

 

 

 

 

 

 

 

 

charging

 

 

 

Transformer drive

 

 

 

 

Photosensitive

 

J301 output enable J136

 

 

signal

 

 

 

 

 

 

 

 

 

 

 

drum

 

-B9

signal

-B4

 

 

 

Transfer cleaning

Cleaning

 

 

 

 

T133

 

 

Transfer output

 

 

Cleaning bias output

bias high-voltage

bias out

 

 

 

 

ON signal

 

transformer

 

 

 

 

-B8

mode signal 4

-B5

 

 

 

(T506)

 

 

 

 

 

 

 

 

 

 

Transfer

 

 

 

 

 

 

 

 

 

 

 

 

 

Serial

 

 

 

Voltage level

 

 

 

 

charging roller

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(ATVC measurement result)

 

 

 

 

 

communication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PCB

Print/standby mode signal

CPU

Voltage

 

 

 

 

detection

 

 

 

 

 

Transfer bias output data

 

 

 

 

 

 

 

 

 

Transfer

 

controller

 

ATVC measurement data

PW-

Transformer drive

 

 

 

 

 

 

Transfer bias

 

bias

 

 

 

 

 

 

 

 

 

 

 

 

signal

 

high-voltage

 

output

 

J301

J136

 

 

 

transformer

 

 

 

 

Transfer bias output

 

(T133)

 

 

 

-A3

 

-A10

 

 

 

 

 

 

 

 

 

 

 

 

DC

 

 

 

 

 

 

 

 

-A1Transfer output-A12

 

 

ON signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-B5

mode signal 1

-B8

 

 

Transfer bias

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transfer output

 

 

output control

 

Current

 

 

 

 

 

 

 

signal

 

 

 

 

 

-B6

mode signal 2

-B7

 

 

 

level

Current

 

 

 

 

Drive

 

 

 

 

 

 

 

 

control

 

detection

Environment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

sensor

 

 

 

 

 

 

 

 

 

 

 

(humidity)

 

 

Transfer output

Transfer bias output

 

 

 

 

 

 

-B7

mode signal 3

-B6

current switching signal

 

 

 

 

 

 

J302-B14

 

 

 

Measurement result

 

 

 

 

 

 

 

 

 

 

 

F04-301-01

 

 

 

 

COPYRIGHT © 2001 CANON INC.

 

 

CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001

4-9 P

Page 173
Image 173
Canon IR2200, IR3300, IR2800 manual Controlling the Transfer Charging Roller Bias, F04-301-01