CHAPTER 6 SELF DIAGNOSIS
6-8 T
E014
000 After the fixing motor drive signal is generated, the clock signal does not
arrive within 1.3 sec.
Main cause The fixing motor (M19) is faulty. The DC controller PCB is faulty.
Action
1. Connector Is the connector of the fixing motor connected?
NO: Connect the connector.
2. Main power supply PCB
Is the drive voltage (24 V) of the fixing motor supplied by the main power
supply PCB?
Main power supply PCB: between J202-3 (24VU1-S) and J202-4 (OVU1)
NO: Replace the main power supply PCB.
3. Fixing motor (M19), DC controller PCB
Press the Start key. Is the lock signal of the fixing motor present at the con-
nector (J312) on the DC controller PCB?
Lock signal: J312-B4 (FSRM_LOCK*)
the DC controller PCB change from 0 to about 5 V?
YES: Replace the fixing motor.
NO: Replace the DC controller PCB.