CHAPTER 2 ORIGINAL EXPOSURE SYSTEM

6)Disconnect the connector [1].

7)Remove the screw [2], and detach the cable fixing plate [3].

8)Push the No. 1 mirror base, and move the No. 2 mirror base [1] as far as the cut-off in the frame; then, free the cable [3] from the pulley [2].

When mounting the lamp, take care not to twist the cable [3].

5.1.2After Replacing the Scanning Lamp

Execute ‘CCD auto adjust’ in service

mode, and record the updated CCD adjust- ment data on the service label.

1.COPIER>FUNCTION>

CCD>CCD-ADJ

CCD Auto Adjust

2.All items under

COPIER>ADJUST>CCD. CCD Adjustment Data

[1][2]

[3]

F02-501-03

[2]

[3]

[1]

F02-501-04