CHAPTER 6 SELF DIAGNOSIS

 

 

 

 

 

 

E051

 

0000

At start-up, home position is not detected when the horizontal registration

 

assembly is moved 100 mm in the direction of home position.

Main cause

The horizontal home position sensor is faulty. The horizontal registration

 

motor is faulty. The DC controller PCB is faulty.

Action

 

 

 

1. Connector

 

 

Are the connectors of the horizontal registration home position sensor and

 

the horizontal registration motor connected?

a.DC controller PCB (J304) <-> relay connector <-> horizontal registra- tion home position sensor

b.DC controller PCB (J304) <-> relay connector <-> horizontal registra- tion motor

NO: Connect the connectors.

2.Sensor lever (damage and interference), Sensor

Is abnormal noise heard from the horizontal registration assembly in keep- ing with the motor rotation?

YES: a. The horizontal registration assembly is out of place because of damage to the sensor lever. Replace the sensor lever.

b. The horizontal registration assembly malfunctions because of the presence of foreign matter. Remove the foreign matter.

c. The sensor is faulty and cannot detect home position. Replace the sensor.

3. Horizontal registration motor, DC controller PCB

Is the horizontal registration motor control signal generated by the DC con- troller PCB?

J304-1/2: 24 V, J304-3/4/5/6: motor excitation signal

YES: The horizontal registration motor is faulty. Replace the motor.

NO: Replace the DC controller PCB.

COPYRIGHT © 2001 CANON INC.

CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001

6-11 T