CHAPTER 5 SERVICE MODE

COPIER>DISPLAY>HV-STS

<HV-STS>

Indicates the measurements taken of voltage/current.

PRIMARY

 

 

 

Indicates the level of current of primary charging in relation to photosensi-

 

tive drum resistance detection control (APVC).

 

Unit: µA

 

 

Reference:

 

 

• If 353 µA or less, the drum unit can well be used.

 

• 353<485 µA or less, the drum unit may be used without a problem.

 

• 485 µA or more, the drum unit should be replaced.

 

 

 

TR

 

 

 

Indicates the mode selected for the level of current of transfer charging.

 

0: transfer constant voltage mode, 1: transfer constant voltage mode (mid),

 

2: transfer constant voltage mode (max.), 3: transfer constant voltage mode

 

(min.)

 

 

 

 

BIAS

 

 

 

Indicates the developing bias DC level (in V)

 

 

 

TR-V

 

 

 

Indicates the voltage level in relation to transfer charging roller resistance

 

detection control (ATVC). (in V)

 

Reference:

 

 

1500 to 6000V:

the transfer charging system is normal.

 

6001V or more:

the transfer charging roller may have a locking fault.

 

1499V or less:

leakage and a transfer charging roller fault

 

 

are possibilities.

 

 

COPIER>DISPLAY>SENSOR

<SENSOR>

 

 

 

 

 

 

 

Indicates the condition of sensors.

 

 

 

 

DOC-SZ

 

Indicates the size of the original detected by the original size sensor.

COPYRIGHT © 2001 CANON INC.

CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001

5-17 T

Page 531
Image 531