CHAPTER 6 FIXING SYSTEM

Fixing film sensor (PS26)

Thermal switch (TP1)

Fixing film

 

 

 

Fixing main heater (H1)

 

 

 

Fixing sub heater (H2)

 

 

Fixing lower roller

 

 

Main thermistor (TH1)

 

Sub thermistor (TH2)

 

Cleaning roller

 

 

 

 

F06-101-02

 

Item

Notation

Description

 

Fixing lower roller

 

Pressure roller

 

Fixing motor

M4

24VDC

 

Main/sub heater

H1, H2

230V model:

637 W

 

 

120V model:

607 W

 

 

100V model:

621 W

Main thermistor

TH1

Temperature control, error detection

Sub thermistor

TH2

Error detection

 

Thermal switch

TP1

Operating temperature: 250 ± 7°C

Fixing film sensor

PS26

Rotation detection; reflection type sensor

T06-101-02

COPYRIGHT © 2001 CANON INC.

CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001

6-3 P

Page 263
Image 263
Canon IR2200, IR3300, IR2800 manual F06-101-02, T06-101-02