CHAPTER 6 SELF DIAGNOSIS

E719

0001

The communication between the Card Reader-C1 or the coin vendor and

 

the main controller PCB is disrupted.

Main cause

The wiring is faulty (short circuit, open circuit). The Card Reader-C1 is

 

faulty. The coin vendor is faulty. The main controller PCB is faulty.

Caution

To clear the error, execute the following in service mode:

 

COPIER>FUNCTION>CLEAR>ERR.

Action

1. Connector

Is the Cad Reader-C1 or the coin vendor connected securely? NO: Connect it securely.

2. Coin vendor, Main controller PCB

Try replacing the Card Reader-C1 or the coin vendor. Is the problem cor- rected?

YES: End.

NO: Replace the main controller PCB.

E732

0001

A fault is detected by the main controller PCB in the communication be-

 

tween reader controller PCB and the main controller PCB.

Main cause

The connector has poor connection. The reader controller PCB is faulty.

Action

1. Connector, Reader controller PCB

Is the connection between the connector J1014 on the main controller PCB and the connector J409 on the reader controller PCB normal?

NO: Correct the connection.

YES: Replace the reader controller PCB.

6-30 T

COPYRIGHT © 2001 CANON INC.

CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001

Page 649
Image 649
Canon IR2800, IR3300, IR2200 manual E719, E732