CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS

6.7.1 Main Controller PCB

J1012

 

 

 

 

 

 

 

J1029

 

J1022

J1060

J1019

 

J1044

 

J1024

 

J1061

J1014

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J1015 J1011

J1013

J1005

 

 

J1059

 

J1006

J1028

SW1002

 

 

J1020

 

J1058

J1010

J1027

 

 

J1001

J1003

J1004

F04-607-01

The DIP switch (SW1002) is designed for adjustments at the factory, and is not normally used in the field.

<When Replacing the PCB>

a.Transfer the following from the old to new PCB:

• shorting connector of J1060

• BOOT ROM of J1010

• SDRAM

• counter memory PCB

b.Protect the back-up data as follows:

1)Back up all data using the Service Support Tool.

2)Replace the main controller.

3)While holding down the keys ‘2’ and ‘8’ of the control panel, turn on the main power (to start download mode). You will not be able to perform the following if you start up in the usual way, since the Box text file data and control data on the hard disk will be ini- tialized.

4)Download all data using the Service Support Tool.

COPYRIGHT © 2001 CANON INC.

CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001

4-79 T