CHAPTER 6 SELF DIAGNOSIS

 

 

 

 

 

 

E601

 

0000

When an image is transferred between the main controller PCB and the

 

HDD, the main controller PCB detects a fault in control information.

0001

When an image is transferred between the main controller PCB and the DC

 

controller PCB, the DC controller PCB detects a fault in the control infor-

 

mation.

Main cause

The wiring is faulty (short circuit, open circuit). The HDD is faulty. The DC

 

controller PCB is faulty. The main controller PCB is faulty

Action

a.E601-0000

1. Wiring

Are the connection and the cable between the connector J1017 on the main controller PCB and the connector J1551 on the HDD normal?

YES: End.

NO: Correct the connection/cable.

2. HDD, Main controller PCB

Try replacing the HDD, and download the system software. Is the problem corrected?

YES: End.

NO: Replace the main controller PCB.

b.E601-0001

1. Wiring

Are the connection and cable between the connector J122 on the DC con- troller PCB and the connector J1015 on the main controller PCB normal?

NO: Correct the connection/cable.

2. DC controller PCB, Main controller PCB

Try replacing the DC controller PCB. Is the problem corrected? YES: End.

NO: Replace the main controller PCB.