COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
CHAPTER 6 FIXING SYSTEM
6-17 P
4.1.9 Removing the Fixing Drive Unit
1) Remove the fixing assembly. (p. 6-13P)
2) Check to see that the feeding assembly
is locked in place.
3) Free the claw of the bushing [1], and
slide it to the front.
4) Remove the locking cam unit [2].
F06-401-15
5) Remove the inside cover. (p. 7-14P)
6) Check to see if the feeding assembly is
released.
7) Disconnect the two connectors [1].
8) Remove the four screws [2], and detach
the fixing drive unit [3].
F06-401-16
4.1.10 Mounting the Locking Cam Unit
1) Check to see if the feeding assembly is
locked in place.
2) Match the arrow of the gear of the lock-
ing cam unit [1] against the middle of
the gear [3] of the fixing drive unit (e.i.,
where the rear [4] of the gear of the
locking cam unit is in contact with the
cut-up [5] of the frame).
F06-401-17
[1]
[2]
[3]
[2]
[1]
[2]
[4] [3]
[1]
[5] [2]