CHAPTER 5 SERVICE MODE

COPIER>ADJUST>HV-PRI

<HV-PRI>

Use it to adjust the output of the primary charging assembly.

If you have cleared the RAM on the DC controller PCB and replaced the PCB, be sure to enter the setting indicated on the service label.

P-DC

 

 

Use it to enter the adjustment value for the primary charging DC compo-

 

nent of the image area.

Range of

0 to 255

adjustment

 

Caution

 

 

 

P-AC

 

 

Use it to enter the adjustment value for the primary charging AC component

 

of the image area.

Range of

0 to 255

adjustment

 

 

 

AGS-GAIN

 

 

Use it to adjust the gain adjustment value for the photosensitive drum resis-

 

tance detection control (APVC) mechanism.

Caution

If you have replaced the composite power supply PCB, be sure to enter the

 

settings indicated on the label attached to the new PCB (case).

Range of

0 to 255

adjustment

 

 

 

AGS-OFST

 

 

Use it to enter the offset adjustment value for the photosensitive drum resis-

 

tance detection control (APVC) mechanism.

Caution

If you have replaced the composite power supply PCB, be sure to enter the

 

settings indicated on the label attached to the new PCB (case).

Range of

0 to 255

adjustment

 

 

 

COPYRIGHT © 2001 CANON INC.

CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001

5-51 T

Page 565
Image 565
Canon IR2800, IR3300, IR2200 manual Hv-Pri, Ags-Gain, Ags-Ofst