CHAPTER 6 SELF DIAGNOSIS

E711

0001

Data is written to the error register of the communication IC (IPC) on the

 

reader controller PCB four times or more within 1.5 sec.

0002

Data is written to the error register of the communication IC (IPC) on the

 

DC controller PCB four times or more within 2 sec.

0003

Data is written to the error register of the communication IC (IPC) on the

 

main controller PCB four times or more within 2 sec.

Main cause

The connector has poor connection. The ADF controller PCB is faulty. The

 

finisher controller PCB is faulty. The DA unit PCB is faulty. The card

 

reader PCB is faulty.

Action

a. E711-0001

Connector, ADF controller PCB

Is the interface cable between the ADF controller PCB an the reader con- troller PCB normal?

NO: Correct the cable.

YES: Replace the ADF controller PCB.

b. E711-0002

connector, Finisher controller PCB

Is the interface cable between the finisher controller PCB and the DC con- troller PCB normal?

NO: Correct the cable.

YES: Replace the finisher controller PCB.

c.E711-0003 Connector, DA unit PCB

Is the interface cable between the DA unit PCB and the main controller

PCB normal?

NO: Correct the cable.

YES: Replace the NE controller PCB.