CHAPTER 4 IMAGE FORMATION SYSTEM

9.5.2 Removing the Grip Assembly

1)Remove the developing assembly. (p. 4- 33P)

2)Remove the screw [1] and free the three claws [2]; then, detach the grip assem- bly [3].

[3]

[2] [1]

9.5.3 Removing the Toner Sensor

1)Remove the grip assembly. (item 9.5.2)

2)Remove the two screws [1], and discon- nect the connector [2].

3)Remove the toner sensor [3].

F04-905-02

[3][2]

[1]

F04-905-03

9.5.4 Removing the Developing Assembly Upper Cover

1)

Remove the grip assembly. (item 9.5.2)

 

2)

Remove the two screws [1], and free the

[2]

 

three claws [2].

 

 

3)

Remove the developing assembly upper

 

 

cover [3].

 

[1]

[3]

F04-905-04

4-34 P

COPYRIGHT © 2001 CANON INC.

CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001