CHAPTER 3 STANDARDS AND ADJUSTMENTS

1.6 Adjusting the Leading Edge Non-Image Width

1)Adjust the non-image width in service mode so that it is as indicated: COPIER>ADJUST>ADJ-XY>ADJ-X.

Decreasing the ADJ-X setting

(A decrease by '12' will decrease the width by 1 mm.)

Image leading edge

Increasing the ADJ-X setting

(An increase by '12' will increase the width by 1 mm.)

F03-106-01

2 Scanning System

2.1 After Replacing the Scanning Lamp

Execute ‘CCD auto adjust’ in service mode, and record the updated CCD adjust- ment data on the service label.

1. CCD Auto Adjust

COPIER>FUNCTION>CCD> CCD-ADJ

2.CCD Adjustment Data All items under

COPIER>ADJUST>CCD.

3-6 T

COPYRIGHT © 2001 CANON INC.

CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001

Page 412
Image 412
Canon IR2800 Scanning System, Adjusting the Leading Edge Non-Image Width, After Replacing the Scanning Lamp, F03-106-01